Lennox EL195UHNE Series Manual page 10

Hide thumbs Also See for EL195UHNE Series:
Table of Contents

Advertisement

Air Gas Plenum
Rollout Switch
(location)
Air Orifice
Gas Orifice
B-Heating Components
Combustion air inducer (B6), primary limit control (S10),
ignitor, burners, flame rollout switch (S47), gas valve
(GV1), combustion air pressure switch (S18), and heat
exchangers are located in the heating compartment. The
heating compartment can be accessed by removing the
outer access panel.
1. Thermal Switch (Figure 5)
The auto-reset switch is located on the front of the air gas
intake. The switch will safely shut the unit down if exces-
sive temperatures are detected. When the switch senses
excessive temperature, the circuit breaks and the igni-
tion control immediately stops ignition and closes the gas
valve.
2. Primary Limit Control (S10)
The primary limit (S10) is located in the heating vestibule
panel. When excess heat is sensed in the heat exchanger,
the limit will open. If the limit is open, the furnace control
energizes the supply air blower and closes the gas valve.
The limit automatically resets when unit temperature re-
turns to normal. The switch must reset within three min-
utes or the SureLight control will go into Watch guard for
one hour. The switch is factory set and cannot be adjust-
ed. The switch may have a different set point for each unit
model number. See Lennox Repair Parts Handbook if limit
switch must be replaced.
HEATING COMPONENTS
Gaskets
Burner Box
Burner
Sensor
Ignitor
Gas Valve
FIGURE 5
Page 10
Heat Exchanger
Primary Limit
3. Burner and Orifice
Burners are factory set and require no adjustment. Always
operate the unit with air gas plenum in place. The burner
has one orifice located between the gas valve and the air
intake assembly (Figure 5). To check or replace the orifice
remove the black iron inlet pipe from the gas valve then
remove the four screws securing the gas valve to the in-
take air pipe. The orifice is located in the orifice housing.
The burner uses an orifice (see Table 16) that is precisely
matched to the burner input. The burner can be removed
for service. If burner has been removed, it is critical to re-
place all gaskets.
TABLE 5
Orifice Size
Unit Input
040
060
080
100
Nat Orifice Size (0 - 7500 ft)
0.0472
0.0595
0.0689
0.0810