Summary of Contents for Channel Lock VJC809PF-C 2001
Page 1
8 GALLON WET/DRY VACUUM MODEL: VJC809PF-C 2001 CAUTION: FOR YOUR SAFETY Read and understand this manual before use. Keep this manual for future reference. Pay close attention to the Rules for Safe Operation, Warnings, and Cautions. You will enjoy years of safe, reliable service if you use your tool properly and only for the purpose for which it is intended.
IMPORTANT SAFETY INSTRUCTIONS Read and understand all instructions before using this vacuum. Read and understand this owner’s manual and all labels on the Wet/Dry Vacuum cleaner before operating. Safety is a combination of common sense, staying alert and knowing how your vacuum works. Use this Wet/Dry Vac only as described in this manual.
Page 4
• Turn off Wet/Dry Vac before unplugging. • Do not put any object into ventilation openings. Do not vacuum with any ventilation openings blocked; keep free of dust, lint, hair or anything that may • and moving parts. • To reduce the risk of falls, use extra care when cleaning on stairs. When using as blower: •...
EXTENSION CORDS When using an extension cord with your Wet/Dry Vac refer to the following table to determine the required A.W.G. wire size. Before using the cleaner make sure the power cord and extension cord are in good working condition. Make repairs or replacements before using the vacuum cleaner.
ASSEMBLY Remove entire contents of carton and check for parts inside the collection tank. Check each item against the Carton Contents List. Carton Content List Key Description Vac Assembly ... . 1 Hose Assembly.
Page 7
GENERAL ASSEMBLY INSTRUCTIONS A Phillips head screwdriver is required. WARNING: DO NOT PLUG IN POWER CORD TO POWER OUTLET, MAKE SURE PLUG IS DISCONNECTED BEFORE ASSEMBLING THE WET/DRY VAC. UNPACKING YOUR WET/DRY VACUUM & GENERAL ASSEMBLY 1. Ensure that the power cord is disconnected from the power outlet. (Fig. 1) 2.
OPERATION VACUUMING DRY MATERIALS WARNING: Be sure to read, understand and apply all the information in the Important Safety Instructions section at the beginning of this vapors, or explosive dusts in the air. Flammable gases or vapors gasoline, alcohol, or aerosol sprays. Explosive dusts include but are not limited to: coal, magnesium, grain, or gun powder.
Page 9
VACUUMING LIQUIDS WARNING: Be sure to read, understand, and apply all the information in the Important Safety Instructions section at the beginning of this vapors, or explosive dusts in the air. Flammable gases or vapors oil-base paints, gasoline, alcohol, or aerosol sprays. Explosive dusts include but are not limited to: coal, magnesium, grain or gun powder.
Page 10
IMPORTANT! When vacuuming large quantities of liquids, do not immerse the nozzle completely in the liquid. Leave a gap at the tip of the nozzle opening to action when the container reaches its maximum capacity. You will notice an increase in motor speed. When this happens, turn off the machine, disconnect from power supply, and drain the liquid into a suitable receptacle or drain.
MAINTENANCE EMPTYING THE COLLECTION TANK 1. Verify that the power cord is disconnected from the outlet. (Fig. 1) 2. Disconnect the hose from the vacuum. (Fig. 2) 3. Undo the latches and remove the power head from the collection tank. (Fig. 3) Place the power head upside down on a soft, clean surface.
Page 12
NOTE: outdoors and not indoors. the inside wall of the container or brush the dirt off. Debris will begin to break up, loosen, and fall. IMPORTANT! ALWAYS USE CARTRIDGE FILTER FOR DRY VACUUMING. If the machine is WARNING: Always disconnect the plug from the power outlet before removing the power head from the collection tank.
Page 13
INSTALLING AND CLEANING FOAM SLEEVE FILTER Installing Foam Sleeve Filter 1. Verify that the power cord is disconnected from the outlet. (Fig. 1) as shown on page 10 “Removing and Cleaning Cartridge Filter”. whole cage is covered. (Fig. 2 & 3) 4.
TROUBLESHOOTING WARNING! TO REDUCE THE RISK OF ELECTRICAL SHOCK - ALWAYS DISCONNECT THE PLUG FROM THE POWER OUTLET BEFORE TROUBLESHOOTING. SYMPTOM CORRECTIVE ACTION POSSIBLE CAUSES Vacuum will not 1. Check power supply - 1. No power supply. operate. cord, breakers, fuses. 2.
EXPLODED VIEW AND PARTS 365297 MANUAL PARTS LIST KEY # PART NUMBER DESCRIPTION 551049101 Handle assembly 551017125 Screw ST3.9*16 Power head 551005103 Water seal cup assembly 551005104 Filter basket 353879 WET/DRY Cartridge Filter Tank 551011106 Suction seat 551002110 Drain cap with gasket 551069105 Caster Foot Assembly 551003111...
WARRANTY We take pride in producing a high quality, durable product. This Channellock® product carries a limited two (2) year warranty against defects in workmanship and materials from date of purchase under normal household use. If product is to be used for commercial, industrial or rental use, a 90 day limited warranty will apply.
Need help?
Do you have a question about the VJC809PF-C 2001 and is the answer not in the manual?
Questions and answers