Download Print this page

jablotron JA-160PC Quick Start Manual page 2

Wireless pir motion detector with a verification camera

Advertisement

JA-160PC Wireless PIR motion detector with a verification camera
Installation recommendations, cautions
Several JA-160PC detectors can be installed in the system. However, triggering
several detectors at the same time will extend the transmission time of photos
to the control panel and to MyJABLOTRON. Complete transmission can take
a few minutes.
In order to take a photo using a PG output, use the F-Link software and set
the Impulse parameter in the PG outputs / Function menu to a time of at least
1 min. The PIR is limited to taking 1 requested photo by PG status per minute.
The number of pre-alarm photos taken by a PG output is limited to 40
photos/day/control panel. The photo counter is reset at 00:00 hrs. Alarm photos
and photos requested in MyJABLOTRON have no limitation.
In the MyJABLOTRON Photo gallery / Sending notifications and in J-Link
software all users have access to the photos from all the system sections.
Installation in the corner of a room requires more attention during testing due
to possible reflection of flash in the photographed scene (especially in the dark).
Detection characteristics
The standard lens that is supplied with the JA-160PC detector covers an area
of 55°/12 m – see picture. The detection characteristics don´t have an influence
on the camera part. The lens must not be changed for any other type. The camera
always has a viewing angle of 43°, the camera flash has a 3-m range.
Side view
PIR
Camera
Saving and browsing the pictures
Every picture is taken as a double exposure: the first with low resolution (LQ =
320 x 240 pixels), second with high resolution (HQ = 640 x 480 pixels).
All of the exposures are saved into the independent folders Foto_LQ and
Foto_HQ on the Micro SD card. When the card is fully loaded, the oldest pictures
are replaced by new ones. Pictures saved on the Micro SD card can be browsed
by a usual PC browser.
Note: Some antivirus software may write their own data on the Micro SD card.
The detector will automatically format the SD card marked this way. SD card
formatting erases all data which has been saved. For more information about
formatting see Formatting the Micro SD card.
Photos are sent to the control panel in LQ. You can browse through the images
by F-Link and J-Link software – event memory, click on the event New image.
Pictures are displayed in LQ, if you click on Detail you can get second-exposure
pictures (HQ). Images can be searched and browsed by a file manager or picture
browser. For another option to show the pictures it is necessary to start F-Link
(J-link) software and be logged into the control panel as a service technician
or Administrator and then under Disc: Flexi_log / Foto photos which have been
sent to the control panel (LQ) and photos which have been requested in Detail
(HQ) are available.
Transfer photos to MyJABLOTRON
When the SIM card supplied by a device manufacturer (distributor) is used and
the customer uses MyJABLOTRON services, then the customer has direct access
to the photos from this service. Parameter settings of the transfer of pictures are
done during the panel registration. All the photos are delivered and visible
in MyJABLOTRON. Every single photo can be requested in HQ resolution.
There you can also choose telephone numbers (for SMS) or e-mail addresses
which will receive a message when a new picture is taken. MyJABLOTRON can
request a new picture without PG output activation
).
recommendations, cautions
WARNING:
This detector allows you to take photos by PG output reaction
or from MyJABLOTRON even when the system is unset. The manufacturer strictly
warns the user that the detector has to be used within the limits given by particular
laws or norms, especially laws about the protection of personal privacy.
The use of the detector is also subject to regulations on the protection
of personal data. The manufacturer recommends the users to familiarize
themselves with these regulations as well as with the regulations governing
the operation of CCTV before the use of the detector. Furthermore,
the manufacturer recommends the users to familiarize themselves with General
Terms and Conditions of Cloud JABLOTRON and with Privacy Policy
(https://gdpr.jablotron.cz/).
JA-160PC Wireless PIR motion detector with a verification camera
According to these regulations users have an obligation to ensure
the approval of persons in range of the detector during the acquisition
of video recordings or the obligation to indicate the image capture area
by information tables
The detector is supplied with a formatted Micro SD card (12). The yellow
indication LED (11) is turned off in normal detector mode. Slow LED flashing
indicates that the card was removed while data was being written on it, or it has
been changed for another SD card. The detector will work normally with a new SD
card only if the detector performs a card formatting. Formatting is started
by pressing the tamper contact (14). The formatting procedure is indicated
by quick flashing of the yellow LED indicator (11). During this process all photos
on the SD card will be erased, however, a back-up of the photos is in the event
memory log.
The detector monitors its own batteries and when they are depleted,
it will inform you about this with a brief flash of the LED indicator when the detector
is triggered. This information is also delivered to the control panel. We recommend
changing the batteries within two weeks from the moment the low battery
indication starts. After replacing the batteries, the detector needs up to 3 minutes
to stabilize (the red LED indicator is lit up). The batteries should be replaced
Top view
by a service technician with the control panel in Service mode. Always replace
both batteries for new ones.
Note: To ensure a proper functionality of the detector we recommend using
batteries supplied by Jablotron distributors (BAT-1V5-AA) or other quality branded
alkaline (lithium) batteries.
Do not throw the batteries in the trash. Deliver them to a civic amenity site
instead.
In case when the F-Link software does not offer an automatic update proceed
by following these steps:
1.
Remove at least one battery from the detector.
2.
Run the F-Link software. Connect the USB cable from your computer
to the mini USB connector (13) inside the detector.
3.
Bootloader mode is indicated by lighting of the red LED and flashing
of the yellow LED.
4.
Then continue the same way as if you want to upgrade the control panel:
Control panel → upgrade Firmware → in the window where you are offered
a device for upgrading select the USB option and type of device.
Power
Typical lifetime
Recommended installation height
Detection angle / detection coverage:
Horizontal camera capture angle
Range of the flash
Resolution of the camera
Photo size LQ/HQ (typically)
Typical (LQ) photo transmission time to the control panel (ideally)
Typical (HQ) photo transmission time from the control panel (ideally)
Typical photo transfer time from the system to the server
Operational environment according to EN 50131-1
Operational temperature range
Dimensions, weight
Classification
According to
Also complies with
Can be operated according to
(see
Installation
2 / 2
.
Formatting the Micro SD card
Changing the batteries
FW upgrade
Technical specifications
2 Alkaline battery type LR6 (AA) 1.5 V
about 2 years (1 activation and 1 series of photos a day)
Please note: Batteries are not included
LQ 320 x 240; HQ 640 x 480 pixels
JABLOTRON ALARMS a.s. hereby declares that the JA-160PC
is in a compliance with the relevant Union harmonisation
legislation: Directives No: 2014/53/EU, 2014/35/EU, 2014/30/EU,
2011/65/EU. The original of the conformity assessment can
be found at www.jablotron.com - Section Downloads.
Note: Although this product does not contain any harmful
materials we suggest you return the product to the dealer
or directly to the producer after use.
2.5 m above the floor
55° / 12 m (basic lens)
43°
max. 3 meters
2-10 kB / 2-64 kB (6 kB / 35 kB)
up to 20 sec. (10 sec.)
up to 130 sec. (60 sec.)
15 s / GPRS; 2 s / LAN
II. Indoor general
-10 to +40 °C
110 x 60 x 55 mm, 102 g
Grade 2
EN 50131-1, EN 50131-2-2
ETSI EN 300 220, EN 50130-4,
EN 55032, EN 60950-1
ERC REC 70-03
MMQ51105