10. Troubleshooting

If the equipment is operated properly you should experience no problems with malfunctions or faults.
In the event of any malfunctions or faults, please check the following before you contact your customer
services.
Fault
Overload cut-out
trips
Charging current
indicators does not
work
Anl_CC_BC_10_E_SPK9.indb 15
Anl_CC_BC_10_E_SPK9.indb 15
GB
Possible cause
- Charger clamps connected incor-
rectly
- Contact between the charger
clamps
- Battery highly discharged
- Battery defective
- Poor contact between the charger
clamps and battery poles
- Battery defective
- Defective charging current indicator
- 15 -
Remedy
- Connect the red clamp to the posi-
tive pole and the back clamp to the
bodywork
- Prevent contact
- Select a lower charging current
- Have the battery checked by an
expert and replace it if necessary
- Clean the contacts and charger
clamps
- Have the battery checked by an
expert and replace it if necessary
- Check the function of the equip-
ment using a diff erent battery