Section 5: Troubleshooting - Prism Hardscapes Embarcadero 60 Installation, Operation & Maintenance Manual

Table of Contents

Advertisement

Section 5   
Refer to the section below according to which Gas Type you purchased. 
BURNER WILL NOT LIGHT 
Possible Cause 
Air in Gas Line 
Debris in Gas Line 
Improper Gas 
Pressure 
 
BURNER WILL NOT STAY LIT 
Possible Cause 
Improper Gas 
Pressure 
Improperly Applied 
Fire Media 
 
NOISE  
Note: Only use gas hose supplied by the manufacturer as they have been tested for noise. 
Possible Cause 
Gas Hose 
Restrictions 
Excessive Gas Flow 
 
UNIT IS SMOKING 
Possible Cause 
Poor Fuel Quality 
 
 
 
 
If newly installed, it may take several attempts to purge air from line. 
Confirm gas line is clear and free of obstruction (insulation, dirt, excess pipe sealer, 
water, etc.). Clearing line of debris may require help from a professional.  
Propane Gas Units: Check if tank is low or empty, may need to refill or replace.  
Natural Gas Units: Have a gas professional confirm gas pressure. 
Propane Gas Units: Check if tank is low or empty, may need to be refilled or 
Natural Gas Units: Have a gas professional confirm gas pressure. 
Media may be too dense; media will need to be reduced and evenly spread. 
Remove any tight bends or kinks in gas supply hose. 
Check gas regulator and reset if not within factory recommendations (Refer to the 
subsection for your gas type in Section 3). 
Propane Gas Units: Inspect propane tank and hose, one or both may need to be 
Natural Gas Units: Contact local gas company.  
 
 
 
Troubleshooting 
How to Fix 
How to Fix 
replaced.  
How to Fix 
How to Fix 
refilled or replaced. 
 
 