Download Print this page

iNels Elko AirTM-100S Quick Start Manual

Pulse converter

Advertisement

Quick Links

ELKO EP, s.r.o.
Palackého 493
769 01 Holešov, Všetuly
Czech Republic
Tel.: +420 573 514 211
e-mail: elko@elkoep.com
www.elkoep.com
Made in Czech Republic
02-21/2019 Rev.: 0
Characteristics
• The Pulse converter counting quantities of pulses from the energy meters (electric-
ity, water, gas).
• The Pulse converter is designed for use on existing gauges even without impulse
output „S0" (gauge must support sensing).
• AirTM-100 converts gauge consumption using sensors - LS (LED sensor), WS (mag-
netic sensor for water meter), MS (magnetic sensor) or pulse output.
• For each power meter it is necessary to have one Pulse converter AirTM-100.
• With the wireless solution and Sigfox communication, it can communicate instant-
ly to your chosen location and be operated immediately.
• Data is sent to the server from which it can be subsequently displayed as a smart-
phone, application, or Cloud notifi cation
• Anti-sabotage: If access to the device is unauthorized, a message is immediately
sent to the server.
• Power supply: 5-12 V DC or 1x 3.6 V batteries SAFT.
• In the case of external power, the battery is automatically disconnected and serves
as backup power.
• Protection degree IP65.
Description
1
3
4
5
+ -
6
7
Cloud app assignment
It is done in your Smartphone application. Enter the relevant information on the product
cover into the application.
Set the sensing type (sensor LS, WS, MS or pulse output S0).
1. Tamper
8
2. Bushing M16x1.5 for connecting
6
cable with max. diameter of 10 mm
3. Programming pins
4. Button SET
5. Setting pins for 3V3 / GND clamp
6. Hole for mounting on the wall Ø
9
4.3 mm / 0.2"
10
7. Power terminal
8. Antenna
11
9. Battery
10. LED indication
2
11. Sensor connection terminal
AirTM-100S
Pulse converter
General instrucions
Internet of Things (IoT)
• The IOT wireless communications category describes the Low Power Wide Area
(LPWA). This technology is designed to provide full-range coverage both inside and
outside buildings, energy-saving and low-cost operation of individual devices. The
Sigfox network is available to use this standard.
Sigfox network information
• The network supports bidirectional communication but with a limited number of feed-
backs. It uses the free frequency band divided by Radio Frequency Zones (RCZ).
RCZ1 (868 MHz) Europe, Oman, South Africa
RCZ2 (902 MHz) North America
RCZ3 (923 MHz) Japan
RCZ4 (920 MHz) South America, Australia, New Zealand, Singapore, Taiwan
• Sigfox has more coverage across countries, so it is better suited for long distance mo-
nitoring.
• For more information on this technology, please visit www.sigfox.com.
Caution for proper operation:
• Products are installed according to the wiring diagram given for each product.
• For proper device functionality, it is necessary to have suffi cient coverage of the selec-
ted network at the installation site.
• At the same time, the device must be registered in the network. Successful device re-
gistration on a given network requires a charge for traffi c.
• Each network off ers diff erent tariff options - it always depends on the number of me-
ssages you want to send from your device. Information on these tariff s can be found in
the current version of the ELKO EP pricelist.
Assembly
1
4b
1. Using a fl at-blade screwdriver gradually slide it into one groove and the other in the lid
and swing open the cover.
2. The product can be attached in two ways:
a) Directly on a fl at surface by gluing * - apply a suitable adhesive to the bottom of the
base. Place the base in the desired location and let it dry.
b) Using a suitable fastener ** by screwing - drill holes into the base with two holes of
suitable diameter corresponding to the position of the holes in the bottom of the box.
Place the base at the desired location and attach it with suitable bonding material
according to the substrate.
3. Thread the sensor through the bushing and plug it in according to the required function
- see chapter Functions, remove jumper (only after setting the function).
4. Connect the supply voltage (via the power supply the transmitter functionality message
is sent to the application)
a. on the clamp
b. Insert the battery and check the correct location.
5. Set the required function (see chapter Function)
1 / 4
2b
4a
5
7
EN
+
-
5-12 V DC
Click!

Advertisement

loading

Summary of Contents for iNels Elko AirTM-100S

  • Page 1 ELKO EP, s.r.o. AirTM-100S Palackého 493 769 01 Holešov, Všetuly Czech Republic Pulse converter Tel.: +420 573 514 211 e-mail: elko@elkoep.com www.elkoep.com Made in Czech Republic 02-21/2019 Rev.: 0 Characteristics General instrucions • The Pulse converter counting quantities of pulses from the energy meters (electric- Internet of Things (IoT) ity, water, gas).
  • Page 2 6. Fill the jumper onto the adjustment pins (see the Function chapter). Restart 7. Replace and snap the front cover. When closing, the handles have to be snapped to their • Open the cover. Power interruption (remove the battery from the device). original position.
  • Page 3 UPLINK / DOWNLINK UPLINK Byte 6 - 0 Function Coun- Coun- Coun- Coun- *Version *Subver- First message 0x01 Tamper: Battery: ter[0] ter[1] ter[2] ter[3] sion FW fl ag: Reserved for future use 1 - opened 1 - low level 1 - fi rst message Coun- Coun- Coun-...
  • Page 4 SET button, programming cable be installed in metal switchboards or in plastic cabinets with metal doors - this prevents transmission of the radio frequency signal. iNELS Air is not recommended for control- Alarm Detection: message to the server...