Ultra P ™ % Flowmeter User Manual
1

Advertisement

Table of Contents
loading

Summary of Contents for Accutron Ultra PC %

  • Page 1 Ultra P ™ % Flowmeter User Manual...
  • Page 2: Warnings And Cautions

    INDIC TIONS FOR USE To be used in nitrous oxide-oxygen sedation systems for delivering to a patient a mixture of nitrous oxide and oxygen gases with a maximum nitrous oxide concentration of 70%. CONTR INDIC TIONS Contraindications for use of nitrous oxide/oxygen inhalation may include: 1.
  • Page 3 C UTIONS Federal (U.S.) law restricts this device to sale by or on order of a dentist or physician. Do not attempt to repair, alter, or calibrate this device. Unauthorized repair, alter- ation or misuse of this device is likely to adversely affect the performance and will void the warranty.
  • Page 4 INDIC TIONS D’UTILIS TION Vous ne devez utiliser cette machine que dans des systèmes de sédation oxygène- oxyde nitreux qui livrent au patient un mélange de gaz d’oxyde nitreux et d’oxygène ayant une concentration maximale d’oxyde nitreux de 70%. CONTRE-INDIC TIONS Les contre-indications sur l’inhalation d’oxyde azoteux/oxygène peuvent inclure: 1.
  • Page 5 TTENTION Conformément à la loi fédérale des États-Unis, cette machine ne peut être vendue que par un dentiste ou par un médecin ou sur leur ordonnance. N’essayez jamais de réparer, de modifier ou de calibrer cet instrument. Toute réparation, modification non autorisée ou mauvais usage de cet instrument nuira considérablement à...
  • Page 7: Table Of Contents

    Table of Contents Page Warnings and Cautions ........2 Upright PC Unit Basic Mechanics .
  • Page 8: Basic Mechanics

    I. PC UPRIGHT UNITS (For Portable & Central Systems) Oxygen Resuscitator Mounting Bracket Connection (3/4" Ø) Serial # Oxygen Flow Tube Inlet DISS Nitrous Oxide Flow Tube O Inlet DISS Oxygen Flush Total Flow Knob Outspout Bottom Mount Threads 1/2 – 20 O Knob Downspout Room Air Override...
  • Page 9: Central System Mounting Options

    PC UPRIGHT CENTR L G S SYSTEM MOUNTING OPTIONS Mobile Stand (Bottom Mount) 2 Gas Supply Lines Connect To Wall Outlet 1/2-20 Threaded Post Mobile Stand Under Cabinet Slide (Back Mount) Mounting Wall Arm Bolt Wall Arm Mounts (Back Mount) Choice of : 9"...
  • Page 10: Portable System Installations

    PC UPRIGHT 2-CYLINDER PORT BLE 17 1/4" 2-CYLINDER PORTABLE -10- SYSTEM ASSEMBLY Flush Identify the following 2000 1000 3000 4000 1000 1000 components in the 2-cylinder portable system package: • Flowmeter 39 3/8" • Portable Manifold (with DISS Hoses and mobile stand attached) •...
  • Page 11 PC UPRIGHT 4-CYLINDER PORT BLE 13 3/16" 16 9/16" -10- Flush 31 5/16" 19" 20 3/4" 1. Mount the flowmeter to the portable manifold: a) Remove the screw and washer from the top of the flowmeter mounting post 4-CYLINDER PORTABLE (located on the manifold).
  • Page 12: Basic Mechanics

    II. PC C BINET MOUNT UNIT (For Central Gas Systems) Mixed Gas Outlet (3/8") Gas Specific Instant Fitting Flow Knob Flow Flow Control Nitrous Oxide Inlet Tube Tube Knob (1/4") Gas Specific Instant Fitting Oxygen Inlet Serial # Mounting Oxygen Flush Resuscitator Label (5/16") Gas...
  • Page 13: Sample Installation

    S MPLE INST LL TION Remote Outlet Options: Ultra PC™ % Flowmeter a) Standard Bag Tee (Contains mixed gas outlet) 1 5 1 0 in Hg b) Remote Flow System (RFS) (Contains mixed gas outlet, and Remote vacuum controller Outlet with gauge display) O 2 &...
  • Page 14: Newport Portable System

    III. Newport 4-Cylinder Portable" Resuscitator Fitting Regulators and E Yokes Cylinders Line Tank Pressure Restraint Gauges Removable Bag Tee Handle Warning: Do not hold handle when opening cabinet.
  • Page 15 Newport Setup and Connections View When looking at the front of the Newport cabinet, Nitrous Oxide is on the left as shown by the blue Nitrous Oxide gauge. Oxygen is on the right as shown by the oxygen gauge. Opening Newport Cabinet Open the Newport cabinet by placing one hand on the front cover and the other in the handle on the side.
  • Page 16 Newport: Managing Gas Supply Identify the two in-use tanks (N O and O ) by attaching “in-use” identification tags to them. When one of the in-use tanks is empty, close the tank by turning the valve clockwise. Leave the empty tank in place. Move the “in-use”...
  • Page 17 Newport: ccessing Serial Number Flowmeter is behind shield at front of unit. Serial # Label...
  • Page 18: Safety Features

    IV. S FETY FE TURES Fail Safe System – Offers assurance that N O ceases if the O supply is inter- rupted or reduced. Emergency Air Valve – Automatically provides patient with ambient air if gas flow is interrupted. Located on remote bag tee. Directional Check Valve –...
  • Page 19 3. CLE NING ND DISINFECTING THE FLOWMETER Cleaning: Clean flowmeter by wiping with moistened towel or spraying with disinfectant and wiping surface. If the disinfectant does not contain a cleaning agent, use a mild cleaner for this step. Disinfecting: Any of the following commercially available disinfectants can be used for disinfecting the flowmeter surface: Commercial Brand Name EPA Registration No.
  • Page 20: Directions For Use

    VI. DIRECTIONS FOR USE Read instructions completely before operating flowmeter device. Note: The steps listed below provide a basic functional description of the flowmeter usage. A training course that emphasizes a practical, hands-on approach combined with instructions on safe techniques for administration of nitrous oxide-oxygen conscious sedation is recom- mended before use of this flowmeter.
  • Page 21: Periodic Equipment Checks

    VII. PERIODIC EQUIPMENT CHECKS Quick Reference Chart N 2 O Flow for Calculating % N 2 O O 2 Flow LPM Check monthly Oxygen Flush Valve Test 1. Make certain the % N O Knob and Flow Knob are turned fully clockwise (off position).
  • Page 22 Check monthly Outspout Check Valve Test 1. Flowmeter should be in the off position. 2. Reservoir bag should be connected to the downspout of the bag tee. 3. Corrugated tube should be connected to the outspout of the bag tee but not connected to patient gas delivery tubing.
  • Page 23: Rubber Goods Attachment

    VIII. RUBBER GOODS TT CHMENT 1. Slide the opening of the reservoir bag over the outside of bag tee downspout. 2. Attach the corrugated tube over the outside of bag tee outspout. 3. Connect “Y” connector of scavenging circuit to the inside of the corrugated tube.
  • Page 24: Troubleshooting Guide

    X. TROUBLESHOOTING GUIDE PROBLEM POSSIBLE C USE REMEDY No flow of O or N 1. O and/or N O supply 1. Turn on O or N O gas not turned on. supply in tank room or on when On-Off is on and O Knob is set at 2.
  • Page 25: Warranty

    XI. W RR NTY ACCUTRON 2-YEAR FLOWMETER LIMITED WARRANTY IF AN ACCUTRON FLOWMETER NEEDS TO HAVE REPAIR WORK OR RE- PLACEMENT PARTS DURING THE 2-YEAR WARRANTY PERIOD DUE TO MANUFACTURING DEFECTS, ACCUTRON WILL PROVIDE THE PARTS AND LABOR AT NO CHARGE. THE FLOWMETER OWNER IS RESPONSIBLE ONLY FOR A $35.OO SHIPPING AND HANDLING FEE, WHICH WILL BE ASSESSED EACH TIME A FLOWMETER IS RETURNED TO ACCUTRON FOR WARRANTY WORK.
  • Page 26: Warranty & Returned Goods Policy

    XII. W RR NTY ND RETURNED GOODS POLICY All warranty resolution issues and merchandize returns will be handled through the local authorized Accutron distributor. Contact distributor where unit was purchased. XIII. REP IR SERVICE POLICY All service issues will be handled through the local authorized Accutron distributor. Contact distributor where unit was purchased.
  • Page 27: Ownership Information

    XV. OWNERSHIP INFORM TION Dr. Name: ________________________________________________________________ Street Address: ____________________________________________________________ City/State/Zip: ____________________________________________________________ Accutron Flowmeter Unit Model: Ultra PC % Ultra PC % Cabinet Mount Newport Flowmeter Serial Number: __________________________________________________...
  • Page 28 1733 W. Parkside Lane • Phoenix, rizona 85027 Toll-free: 800-531-2221 • Local Phone: 623-780-2020 • Fax: 623-780-0444 www.accutron-inc.com...

This manual is also suitable for:

Ultra pc % cabinet mountNewport

Table of Contents