Installation instructions
Barrier
14 English
Install_DOC30P977D_DG68-01317A-00_EN+MES+CFR.indb 14
3.
Push oven completely into the cabinet
and center the oven into the cabinet
cutout.
4.
Remove the tape from front trims.
Securely fasten the oven to the
cabinet using the screws provided.
Insert the screws through hole in
trim aligning with hole in lower
oven frame. Do not overtighten
screws.
WARNING
When inserting the oven, use caution not to
deform or damage the barrier underneath.

Self-diagnosis

Temp sensor & Heater check
1.
After connecting the power, check if the display works properly.
2.
Remove all accessories (Gliding Rack, Flat-Rack...etc.) from inside of the oven
cavity.
3.
You cannot proceed with self-diagnosis if the oven cavity is hot or the door is
open.
In this case, "Hot or door" message appears on the display.
4.
To start self-diagnosis, press both Hidden Keys simultaneously for 5 seconds.
Refer to the table below for the hidden keys for each model.
Self-diagnosis takes approximately 4 ~ 5 minutes.
Model
Control panel
Hidden Key
MICROWAVE + LOWER OVEN
5.
If there is no error, 'PASS' appears on the display with an alert sound.
6.
If there is an error, following message appears on the display with an alert
sound.
Model
Error code
H-4
Lower Broil
Feature
Lower Bake
H-3
7.
If an error occurs, contact a Dacor service center for further service.
NOTE
Please contact Dacor Distinctive Service Center at 833-35-ELITE (833-353-5483).