ELECTRICAL CIRCUIT
Power
Cold
See Diagram
Blk
Control
Defrost
Yel
Timer
On/Off
Thermostat
Or
Defrost
Blu
Thermostat
Red
Ambient
Thermostat
Blk
Fan Relay
Pur
Brn
Door
Switch
EC82
SYSTEM SCHEMATIC
Condenser
Outlet
Charge Tube
Drier
SP24
IMPORTANT
If any green grounding
Wh
wires are removed dur-
ing
servicing,
Compressor
must be returned to
their original position
and properly secured.
Defrost
Heater
WIRING DIAGRAM
Wh
Yel
Yellow
Jaune
Yel
Armarillo
Evaporator
Fan
C
Pur
R
S
Relay
Auxiliary
Relais
Heater
White
Blanc
Rele
Blanco
Interior
Light
Heat Exchanger
Charge
Tube
Discharge
IMPORTANT SAFETY NOTICE
The information provided herein is
designed to assist qualified repair
personnel only. Untrained persons
they
should not attempt to make repairs
due to the possibility of electrical
shock. Disconnect power cord
before servicing.
INSTALLATION
This product is designed for "free standing installation only" and three inches of
clearance must be provided on all sides of the refrigerator for air circulation.
The refrigerator should be positioned on a solid floor, and the front of the cabinet
Overload
should be raised just enough to provide easy door closure when open about half
Surcharge
Protector termico
way.
de sobrecarga
REFRIGERANT CHARGE AND ELECTRICAL SPECIFICATIONS
Refer to serial plate.
TEMPERATURE CONTROL
38.5°F cut in, 32.0°F cut out @ number 1 setting.
C09
DEFROST CONTROL
An automatic 30 minute defrosting period is initiated after every 12 hours of compres-
sor running time. During the defrosting period, a thermostat will switch the defrost
heater off after the frost on the evaporator has melted. The defrost thermostat closes at
10°F and opens at 50°F.
FREEZE CONTROL
When the external temperature falls below 35° ± 3°F a 40 watt auxiliary heater and
the evaporator fan will turn on. Both will run until either:
A)
The interior cabinet reaches the temperature selected by the
temperature control, causing the auxiliary heater to turn off and
the compressor and fan to run.
B)
The external temperature reaches 45° ± 5°F and the fan and auxiliary
heater turns off.
216946200
SERVICE DATA SHEET
AUTOMATIC DEFROST
SINGLE DOOR
REFRIGERATOR
PD636

Advertisement

loading

Summary of Contents for Frigidaire FRU17G4JW9

  • Page 1 Jaune Armarillo The refrigerator should be positioned on a solid floor, and the front of the cabinet Overload should be raised just enough to provide easy door closure when open about half...
  • Page 2 Commande Blanc Noir de froid Jaune Thermostat Compresseur Orange Bleu Rouge Blanc Thermostat Jaune d'Ambiant Noir Ventilateur de vaporisateur Relais de Violet ventilateur Violet Brun Interrupteur Lampe de porte intérieure FEC82 SCHÉMA DU SYSTÈME Échangeur Sortie du du chaleur condenseur Tube de charge Déshydrateur Refoulement...

This manual is also suitable for:

Fru17b2jw - 17 cu. ft. all refrigeratorFru17g4jwFru17b2jw