National Instruments NI PXI-2567 Safety, Environmental, And Regulatory Information

National Instruments NI PXI-2567 Safety, Environmental, And Regulatory Information

Advertisement

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION
NI PXI-2567
This document includes compliance precautions and connection information for the NI PXI-2567.
Note The guidelines in this document are specific to the NI 2567. The other components in the system might not meet the same ratings. Refer to the
documentation for each component in the system to determine the safety and EMC guidelines for the entire system.

Safety Guidelines

Operate the NI 2567 only as described in the device user documentation.
Caution Do not operate the NI 2567 in a manner not specified in the user documentation. Product misuse can result in a hazard. You can compromise
the safety protection built into the product if the product is damaged in any way. If the product is damaged, return it to NI for repair.

Safety Voltages

Connect only voltages that are within these limits.
Maximum drive voltage
Note Overvoltage protection activates at 80 V maximum.

Electromagnetic Compatibility Guidelines

This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications.
These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational
electromagnetic environment.
This product is intended for use in industrial locations. However, harmful interference may occur in some installations, when the product is connected to a
peripheral device or test object, or if the product is used in residential or commercial areas. To minimize interference with radio and television reception and
prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation.
Furthermore, any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your
local regulatory rules.
Caution To ensure the specified EMC performance, operate this product only with shielded cables and accessories.
Caution To ensure the specified EMC performance, the length of all I/O cables must be no longer than 3 m (10 ft).

Preparing the Environment

Ensure that the environment in which you are using the NI 2567 meets the following specifications.
Environment
Operating temperature
Storage temperature
Operating relative humidity
Storage relative humidity
Pollution Degree
Maximum altitude
Indoor use only.
50 VDC
0 °C to 55 °C
-20 °C to 70 °C
10% to 90%, noncondensing
5% to 95%, noncondensing
2
2,000 m

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NI PXI-2567 and is the answer not in the manual?

Questions and answers

Summary of Contents for National Instruments NI PXI-2567

  • Page 1 Furthermore, any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules.
  • Page 2 For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product.

Table of Contents