6.2.2.
Remove the water collection tank and empty the water out of it. Remove the tank cover and wash the inside of the tank with clean
water. The tank may be scratched if it is scrubbed strongly with a brush. DO NOT remove the float lever from the tank. Wipe off the
water on the outside of the tank with a cloth. Refit the tank cover onto the tank and replace the tank in position.
6.2.3.
Clean the air filter (see 6.1).
6.2.4.
When the unit is to be stored for a long time, wipe the dehumidifier over with a dry soft cloth. To remove dirt, wipe over with a very
slightly dampened cloth (never use a wet cloth for cleaning the controls). To avoid deformation or cracking, do not use benzine,
thinner or liquid cleaners.
6.2.5.
When storing, place in a safe, dry, childproof location. Stand the unit upright and avoid exposure to direct sunlight.
7. TROUBLE SHOOTING
7.1.
Upon fault of the dehumidifier, please cut off the power supply immediately, unplug the plug and check the following items:
Faults
Cause Analysis
Shown as no power
Fails to turn on
Shown as power on
If the air inlet/outlet is obstructed.
Unfavourable
If the door and window are open.
dehumidifying effect
If the indoor temperature is too low.
If the ground is firm and flat.
Heavy noise
Dehumidifier is stood precariously.
Dehumidifier stood on an incline.
Water leakage
Drain pipe/outlet obstructed.
Coil sensor fault
E1
E2/E3
Fault of humidity & temperature sensor.
Refrigerant leakage.
EE
7.2.
If the said methods still fail to eliminate the above problems, please directly contact the manufacturer or agents. DO NOT disassemble
the dehumidifier, contact Sealey for repairs.

ENVIRONMENT PROTECTION

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
No power to the wall socket.
Check the plug plugged in
properly.
Check the fuse is not blown.
Power Transformer is broken.
Environmental humidity lower
than the set value.
If the water tank is installed
correctly.
If the entire machine is defrosting.
01284 703534
sales@sealey.co.uk
Original Language Version
Solutions
Check the power supply.
Plug the power supply in the socket.
Replace the fuse.
Replace the transformer.
Set again according to the demand.
Place the water tank in right position.
Wait for the completion of defrosting cycle.
Remove the obstacle.
Close the door and window.
Don't run the dehumidifier.
Resettle the dehumidifier.
Resettle the dehumidifier.
Move dehumidifier to a level surface.
Dismantle the front plate to eliminate blockages.
Turn to timing for defrosting, to cancel system fault
function.
Replace the humidity & temperature sensor.
Start the machine after. Ask for help from
professionals if the "EE" signal remains.