5.5.
CONTINUOUS DRAINING
5.5.1.
If there is a place suitable for draining, continuous draining can be carried out. The continuous operation enables the dehumidfying
operation to continue uninterrupted. See Section 4.6.

6. MAINTENANCE

CLEANING THE AIR FILTER

6.1.
6.1.1.
The dehumidifying capacity is lowered when the air cleaning filter becomes clogged.
6.1.2.
Open the front door of the unit.
6.1.3.
Lift up the filter element from the bottom and lift out of the holder.
6.1.4.
To dislodge the dust from the filter, use a vacuum cleaner or tap it lightly.
6.1.5.
If the filter is very dirty, wash it carefully in water with a neutral detergent, then rinse well with clean water and leave until dry.
6.1.6.
To refit the air filter locate the top of the element into the locating bracket at the top of the door and then locate the lower section into
the lower bracket.
6.1.7.
Close the door of the dehumidifier.
STORAGE
6.2.
6.2.1.
Unplug the unit, bundle the power cord, and hang the bundled cord at the back of the unit.
6.2.2.
Remove the water collection tank and empty the water out of it. Remove the tank cover and wash the inside of the tank with clean
water. The tank may be scratched if it is scrubbed strongly with a brush. DO NOT remove the float lever from the tank. Wipe off the
water on the outside of the tank with a cloth. Refit the tank cover onto the tank and replace the tank in position.
6.2.3.
Clean the air filter (see 6.1).
6.2.4.
When the unit is to be stored for a long time, wipe the dehumidifier over with a dry soft cloth. To remove dirt, wipe over with a very
slightly dampened cloth (never use a wet cloth for cleaning the controls). To avoid deformation or cracking, do not use benzine,
thinner or liquid cleaners.
6.2.5.
When storing, place in a safe, dry, childproof location. Stand the unit upright and avoid exposure to direct sunlight.
7. TROUBLE SHOOTING
Faults
Cause Analysis
Shown as no power
Fails to turn on
Shown as power on
If the air inlet/outlet is obstructed.
Unfavourable
If the door and window are open.
dehumidifying effect
If the indoor temperature is too low.
If the ground is firm and flat.
Heavy noise
Dehumidifier is stood precariously.
Dehumidifier stood on an incline.
Water leakage
Drain pipe/outlet obstructed.
Coil sensor fault
E1
E2/E3
Fault of humidity & temperature sensor.
Refrigerant leakage.
EE
© Jack Sealey Limited
No power to the wall socket.
Check the plug plugged in
properly.
Check the fuse is not blown.
Power Transformer is broken.
Environmental humidity lower
than the set value.
If the water tank is installed
correctly.
If the entire machine is defrosting.
Original Language Version
Solutions
Check the power supply.
Plug the power supply in the socket.
Replace the fuse.
Replace the transformer.
Set again according to the demand.
Place the water tank in right position.
Wait for the completion of defrosting cycle.
Remove the obstacle.
Close the door and window.
Don't run the dehumidifier.
Resettle the dehumidifier.
Resettle the dehumidifier.
Move dehumidifier to a level surface.
Dismantle the front plate to eliminate blockages.
Turn to timing for defrosting, to cancel system fault
function.
Replace the humidity & temperature sensor.
Attempt shut down and restart, if no change seek help
from professionals if the "EE" signal remains.