Download Print this page
Sealey SDH50.V4 Instructions Manual
Sealey SDH50.V4 Instructions Manual

Sealey SDH50.V4 Instructions Manual

50l industrial dehumidifier

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Do not cover
instructions
1. SAFETY
1.1.
ELECTRICAL SAFETY
1.1.1.
Save all warning and instructions for future reference.
WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following: You must check
all electrical products before use to ensure that they are safe. You must inspect power cables, plugs, sockets and any other connectors
for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A
Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual
Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is
not protected by an RCCB. If in any doubt consult a qualified electrician. You must also read and understand the following instructions
concerning electrical safety:
1.1.2.
The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances
and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3.
Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
1.1.4.
Ensure that cables are always protected against short circuit and overload.
1.1.5.
Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none are loose.
1.1.6.
Important: Ensure that the voltage marked on the appliance matches the power supply to be used and that the plug is fitted with the
correct fuse.
DANGER! If the power cable for this equipment is damaged, it must be replaced by the manufacturer or its after-sales service or similarly
trained personnel to avoid danger.
DO NOT pull or carry the appliance by the power cable.
8
DO NOT pull the plug from the socket by the cable.
8
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a
9
hazard."
DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty item repaired or replaced by a qualified electrician.
8
1.1.7.
Over/current Protection: The user has to make provision for the installation of the over-current protection of the power circuit.
1.1.8.
Electrical disconnecting device: The user has to make provisions for the installation of the electrical disconnecting device of the power
circuit. The supply disconnection device is to be in accordance with EN 60204-1:2006.
1.2.
GENERAL SAFETY
The appliance shall be disconnected from its power source during maintenance.
9
Always operate the unit from a power source of equal voltage, frequency and rating as indicated on the product identification plate.
9
Always use a power outlet that is grounded.
9
Unplug the power cord or disconnect the power source (RCD) when cleaning or when not in use.
9
DO NOT stand or place any object less than 10cm from the front or rear of the unit.
8
DO NOT obstruct the air intakes or outlets of the dehumidifier.
8
Always discard the water from the collection tank.
9
DO NOT use it for any other purpose.
8
Place the dehumidifier on a level and stable surface.
9
DO NOT use the dehumidifier at ambient temperatures below 5°C.
8
DO NOT operate with wet hands. Prevent water from spilling onto the unit.
8
DO NOT immerse or expose the unit to rain, moisture or any other liquid.
8
DO NOT leave the unit running unattended. Do not tilt or turn over the unit.
8
DO NOT unplug while the unit is operating.
8
DO NOT unplug by pulling on the power cord.
8
DO NOT use an extension cord or an adapter plug.
8
DO NOT put objects on the unit.
8
DO NOT climb or sit on the unit.
8
DO NOT insert fingers or other objects into the air outlet.
8
DO NOT touch the air inlet or the aluminium fins of the unit.
8
DO NOT operate the unit if it is dropped, damaged or showing signs of product malfunction.
8
DO NOT clean the appliance with any chemicals.
8
Ensure the unit is far away from fire, inflammable, or explosive objects.
9
The unit shall be installed in accordance with national wiring regulations.
9
© Jack Sealey Limited
50L INDUSTRIAL DEHUMIDIFIER
SDH50.V4
MODEL NO:
Warning!
Indoor use only
Risk of fire
Original Language Version
SDH50.V4 Issue 6 08/07/24

Advertisement

loading
Need help?

Need help?

Do you have a question about the SDH50.V4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sealey SDH50.V4

  • Page 1 SDH50.V4 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 This shall be reported to the owner of the equipment so all parties are advised. SDH50.V4 Issue 6 08/07/24 Original Language Version...
  • Page 3 If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system. Make sure that cylinder is situated on the scales before recovery takes place. Start the recovery machine and operate in accordance with instructions. DO NOT overfill cylinders (no more than 80 % volume liquid charge). SDH50.V4 Issue 6 08/07/24 Original Language Version © Jack Sealey Limited...
  • Page 4 Power Supply Cable Length: ........1.5m Power: ..Rated – 545W ( 27°C RH60%), Max – 650W ..............(30°C RH80%) Refrigerant: ..........R290/0.230kg Steaming Pressure (Max):........3.2MPa Supply: ............230V ~ 50Hz Working Space: ..........50-120m³ BACK Working Temperature: .........5-38°C 4. FEATURES Features are as in fig.1. fig.1 SDH50.V4 Issue 6 08/07/24 Original Language Version © Jack Sealey Limited...
  • Page 5 MINUS Each press of this button will decrease the set humidity level/timer by 5%/1 hour within the range of 20-90%/0-24 hours. ADD Each press of this button will increase the set humidity level/timer by 5%/1 hour within the range of 20-90%/0-24 hours. SDH50.V4 Issue 6 08/07/24 Original Language Version © Jack Sealey Limited...
  • Page 6 Open the front cover, remove the tank, and clear the water from the tank. 6.6.2. Remove the plug and install the included drain pipe to the connector, direct the pipe to the desired area before operate the machine. See the pictures below. SDH50.V4 Issue 6 08/07/24 Original Language Version © Jack Sealey Limited...
  • Page 7 The appliance must be kept in an upright position when in storage. NOTE: Manual drainage can help with completely drying the appliance. fig.5 SDH50.V4 Issue 6 08/07/24 Original Language Version © Jack Sealey Limited...
  • Page 8 Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 sales@sealey.co.uk...