28
Table 19. Supported Parameters
Parameter
(wValue)
0
1
2
Response
The parameter data is sent to the host in a Parameter Data report. All parameter data is
treated as if it were stored as bytes. This means that multi-byte values will be sent MSB
first.
If the command cannot be processed, the device stalls endpoint 0. The command cannot
be processed if the parameter number is not valid. It cannot be processed if less than 4
bytes (wLength) are requested. It cannot be processed if more data is requested than is
contained in the parameter.

Parameter Data Report 4

This report is sent in response to any request for parameter data. All parameter data is
treated as if it were stored as bytes in the order that it is stored in memory. This means
that multi-byte values will be sent MSB first.
Table 20. Parameter Data Report
Offset
0
1
3
Data size – the number of data bytes to follow.
Data byte – At least 1 data byte will follow when data size is greater than zero. The
number of data bytes returned by this report is limited by the "Max Param Write" value
returned by the Controller ID report. The contents of this data section are dependent on
which parameter is being accessed.
wLength
wIndex
(bytes+3)
0
0
0
5
0
7
Field
Report ID
Data size
Data bytes
3M Touch Systems, Inc. Proprietary Information – TSD-40848A
3M™ MicroTouch™ Controller EX Dual Mode Reference Guide
Range
Description
0
Reserved for future use
0 – 3
Sensor orientation - where the lower left
corner of the display maps to the sensor.
0000 – Upper right
0001 – Lower right
0002 – Upper left
0003 – Lower left (standard, not rotated)
32
0 – 2
-1 Controller serial number
Size
Value
1
0x04
2
0xXXXX
Data Size
0xXX
Description
Report ID number
Amount of data to follow
Data bytes