Installing 3M™ Microtouch™ Software - 3M MicroTouch EX113 Reference Manual

Dual-mode controller
Table of Contents

Advertisement

14
Self Test
LED
Condition
Flashes
Backplane
16
Error
Corner Error
17
Fixed Cal Error
18
Note 1: this is a fatal error.
Note 2: this error is detected by the ROM code
Note 3: indicates that the EEPROM is not formatted when given by the ROM code
Installing 3M™ MicroTouch™ Software
3M™ MicroTouch™ Software includes the driver that enables your sensor to work with
your computer. 3M Touch Systems has touch drivers for many operating systems,
including Windows® 7, Windows® Vista, Windows® XP, Windows® XP embedded,
Windows® CE, and Linux® (Kernel 2.6) (refer to the website for a complete listing).
You must be sure to install the correct software for your operating system.
3M™ MicroTouch™ Touch Solutions include a control panel for setting your sensor
preferences and a diagnostic utility. If you are experiencing problems with the sensor,
you can use the diagnostic utilities provided to locate the controller and test the sensor.
For more information on connecting your cables and installing and using the sensor
control panel and utilities, refer to the 3M™ MicroTouch™ Software User Guides
available on the corporate website at www.3Mtouch.com.
Self
Test
Bit
Description
15
Low resistance path from
backplane to sensor
16
Corner drive offset level is
too high
17
Fixed 2-point cal error high
3M Touch Systems, Inc. Proprietary Information – TSD-40848A
3M™ MicroTouch™ Controller EX Dual Mode Reference Guide
What to do...
Cycle power. If fault persists,
replace sensor.
Cycle power. If fault persists,
replace controller.
Cycle power. If fault persists,
replace controller.

Advertisement

Table of Contents
loading

Table of Contents