Biotek EOS7150-H Instruction Manual
Biotek EOS7150-H Instruction Manual

Biotek EOS7150-H Instruction Manual

Hydrogen water pot

Advertisement

Quick Links

HYDROGEN WATER POT
INSTRUCTION MANUAL
EOS7150-H / EOS7150-HG
Thank you for purchasing this Biolux product.
Please read the instructions carefully and follow the safety precautions when using this product. Before
using this product please pay special attention to the "IMPORTANT SAFEGUARDS" (P. 2~4).
This product is intended for household use only.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EOS7150-H and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Biotek EOS7150-H

  • Page 1 HYDROGEN WATER POT INSTRUCTION MANUAL EOS7150-H / EOS7150-HG Thank you for purchasing this Biolux product. Please read the instructions carefully and follow the safety precautions when using this product. Before using this product please pay special attention to the “IMPORTANT SAFEGUARDS” (P. 2~4).
  • Page 2: Table Of Contents

    System Menu & Settings P.22 LED Effect P.22 Info / Setting P.23 Cleaning & Maintenance P.24 Troubleshooting P.26 Q&A on Product Use P.28 The illustrations used in this Instruction Manual may vary from the actual product that you have purchased. EOS7150-H/HG-EN_V112...
  • Page 3: Important Safeguards

    IMPORTANT SAFEGUARDS Basic safety precautions should always be followed when using electrical appliances, including the following: 1. Read all instructions thoroughly. 2. Avoid touching hot surfaces and do not block or clog the gas vent opening under any circumstances. 3. To safeguard against fire, electric shock and possible injury, keep the power cord, plug and the appliance away from water or other liquids.
  • Page 4 Before Use These WARNINGS and CAUTIONS are intended to protect you and others from personal injury and household damage. To ensure safe operation, please follow carefully. WARNINGS This product generates hydrogen gas. While Do not use the product if the Power Plug or Power normal use of this product would not create an Cord is damaged or if the Power Plug is loosely explosion hazard, care must always be taken when...
  • Page 5 CAUTIONS This product is not intended for used by persons Allow the product to dry completely when storing (including children) with reduced physical, sensory the product in areas where it may freeze for a period or mental capabilities, or lack of experience and of time.
  • Page 6: Main Features

    MAIN FEATURES The Biolux EOS7150 Series (EOS7150-H & EOS7150-HG) Hydrogen Water Pot has been developed to produce hydrogen enriched drinking water. The of EOS7150-HG model provides a source of high purity hydrogen gas for inhalation. Other features include: Safety Automatic Shut-Off...
  • Page 7: Specifications

    SPECIFICATIONS HYDROGEN WATER POT SPECIFICATIONS EOS7150-HG EOS7150-H Model No Heating function up to 80℃ (176℉) Features Hydrogen Enriched Water Hydrogen Enriched Water Hydrogen Gas 1.8 L Capacity AC 100 - 120V, 50/60Hz or AC 220 - 240V, 50/60Hz Voltage 200W Rated Power >...
  • Page 8: Parts And Handling Instructions

    PARTS & HANDLING INSTRUCTIONS Part Discriptions Filter Chamber Cannula Connector (Accessory, EOS7150-HG exclusive) • Install Filter and pour RO water • Used for cannula connection to the Lid Opening Lever for electrolysis in here. Lid Vent in Model EOS7150-HG. For use instructions, see pg.19.
  • Page 9 Control Panel A LIGHT TOUCH is all that is required when pressing buttons EOS7150-H DISPLAY • Displays operating information and explanatory texts. START light DISPENSE light HEATING light MENU light TEMP SET button MENU button • Press to perform Menu Functions •...
  • Page 10: Preparation Before Using

    PREPARATION BEFORE USING How to Detach / Attach the Front Lid How to Open / Close the Upper Lid Lift the Front Lid to about a Hold the Pot Body down. To Detach To Open 15-degree angle. Pull the Front Lid forward to Lift up the Upper Lid using remove.
  • Page 11 Water to be Added into the Inner Container Filtered and / or Purified Water is Do not use local tap water, Recommended which is unfiltered. The water in the Inner Container is for hydrogen enrichment and drinking. The water quality must meet your local drinking water standards.
  • Page 12 Assemble the Filter Lever onto the Filter Cartridge. Open the Front Lid and attach the Filter Cartridge at the bottom of the Filter Chamber Remove the Spout cap and plug the product to a standard AC outlet The product takes 10 sec to start up.
  • Page 13 Fill the Filter Chamber with the appropriate quality of water to the MAX line Pour in water with a pitcher, bottle or MAX line another container. Approx. 300ml • Please refer to pg.09 for the operating guideline on adding water to the Filter Chamber. •...
  • Page 14: How To Use

    HOW TO USE The first time you use the new product you may notice the smell of plastic. This is normal and will gradually go away. Be sure to attach the Filter Cartridge, fill the Filter Chamber and Inner Container with the proper required quality of water to the MAX line before proceeding to operate.
  • Page 15 Automatically Maintaining Peak Concentration Once the hydrogen water concentration reaches the peak - 1,200ppb, the system will start the "Automatically Maintaining Peak Concentration" mode to maintain this saturated status automatically. Blinks Blinks Reduced amount and/or having smaller sizes of bubbles during period of "Automatically Maintaining Peak Concentration"...
  • Page 16: Heating Function

    Hydrogen Water Production OFF Press and hold the button for 3 seconds. During Hydrogen Water Production ON / Automatically Maintaining Peak Concentration Light OFF Steady ON * 3 seconds Heating Function Heating & Maintaining Temperature ON Press once on the button to unlock.
  • Page 17 Heating & Maintaining Temperature ON Press again on the button to start Heating & Maintaining Temperature based on settings. During the function unlocked period. Current / Set Blinks Slowly Blinks Temperature 3 seconds Maintaining Temperature Steady ON Heating Changing Temperature Settings Press the button twice to change temperature settings (PS.
  • Page 18 Automatically Resuming Peak Production During Heating The "Automatically Resuming Peak Production" function is available while Heating Function is activated. When refilling new water in the Inner Container and there is a detection of 3˚C (7˚F) reduction during the Heating Function is on, the system will reactivate the Resuming Peak Production automatically.
  • Page 19: Dispensing Hydrogen Water

    Dispensing Hydrogen Water Press the button to unlock The DISPENSE green light blinks, the function is unlocked and water can be dispensed now. Blinks • When the DISPENSE light is off, water cannot be dispensed. Press the button again to dispense water Activate dispensing with a gentle touch on the button again within 3 sec after...
  • Page 20: How To Dispose Water

    How to Dispose Water Dispense as much water Unplug the Power Cord Detach the Front and out as possible Upper Lid and remove the Drip Grid and Tray • There could still be a little water remaining in the Pure Water Chamber after draining through the Drain Tube.
  • Page 21: Gas Delivery (Hydrogen Inhalation)

    Gas Delivery * This is a function available exclusively to EOS7150-HG Gas Delivery Timer Settings Default Press the button to change and activate the Gas Delivery Timer settings. Timer 30:00 60:00 Under Hydrogen Water Production Hydrogen Lv. 1200 ppb Peak Gas Delivery Timer OFF Automatic OFF based on timer settings, or Press once on the...
  • Page 22 Gas Delivery Timer In Use Press on the button to start the Gas Delivery Timer. Under Hydrogen Water Production Steady ON Hydrogen Lv. 1200 ppb Peak Starts timer *60:00 alternative Timer is available by pressing the button Heating is stopped automatically one more time.
  • Page 23: System Menu & Settings

    SYSTEM MENU & SETTINGS Enter System Menu Press and Hold on the button for 3 seconds to enter system setting menu. Under Standby In EOS7150-HG * 3 seconds Select Resume to return the standby mode. Select LED Effect to turn on/off the lighting effects. Select Info/Setting to enter system information and replacement reset.
  • Page 24: Info/Setting

    Info/Setting Select Language to change System Select Temperature to change Language settings Temperature unit settings Select System Info to check the working status, part’s remaining life and to reset the life after replacement. In good condition. Service due (remaining life less than 2% or has finished, or a failure has been detected) Resume to Standby once completed...
  • Page 25: Cleaning & Maintenance

    Always unplug the Power Cord, Remove the Filter, detach the Drip Grip CLEANING & MAINTENANCE and Tray, dispose all water, and allow to cool completely before cleaning • Do not use a thinner, benzene, abrasive cleansers or brushes (nylon or metal) detergents, alkaline soaps, bleach or anything that may damage the surface of the product.
  • Page 26 How to Replace the Inner Lid Gasket The Inner Lid Gasket may need to be replaced due to wear and tear. Check it once a year. Pry out and pull off the old Inner Lid Gasket from the outer When the Inner Lid Gasket turns hard and white (the original circumference.
  • Page 27: Troubleshooting

    TROUBLESHOOTING Please check the following possible causes and/or solutions before calling for service. Possible Cause If... Solution No power or the Power Plug is Check the mains, plug and not connected. voltage. Connect the Power Plug. No Display Water damage. Call customer service for repair.
  • Page 28 Possible Cause If... Solution No power or the Power Plug is Check the mains, plug and not connected. voltage. Connect the Power Plug. Observed no bubbling Is the Hydrogen Water Press (start icon) button to start Production function activated? the function. Electronic failure.
  • Page 29: A On Product Use

    If... Possible Cause Solution Check “System Info” for indication Display shows “Service (see pg.23 for instructions). Part(s) due for replacement. Replace as indicated or call Due” message customer service. Display shows “System Replace the Cell as needed or Hydrogen Cell malfunction. call customer service for repair.
  • Page 30 MEMO...
  • Page 31 MEMO...
  • Page 32 Biotek Environmental Science Ltd. www.besgroups.com Rev. A202008_EN_BES...

This manual is also suitable for:

Eos7150-hg

Table of Contents