Electrolytic Ozone WATER DISINFECTION SYSTEM Model EOS7177-PQ INSTALLATION & OPERATION MANUAL BIOTEK ENVIRONMENTAL SCIENCE LTD. www.besgroups.com...
Page 3
BioSure Professional Model EOS7177-PQ. BioSure is a division of Biotek Environmental Science Ltd. ("BES"). BES is a global leading electrolytic technology developer and product manufacturer with pioneering ozone application knowledge and currently holds many exclusive patents for its electrolytic ozone generators and products worldwide.
TABLE OF CONTENTS TABLE OF CONTENTS PACKAGING CONTENTS IMPORTANT SAFETY INFORMATION 1. PRODUCT INFORMATION 1.1 PRODUCT DESCRIPTION 1.2 KEY COMPONENTS 1.3 SPECIFICATIONS 2. INSTALLATION 2.1 PRECAUTIONS BEFORE INSTALLATION 2.2 INSTALLING THE UNIT 2.3 REMOVE THE UNIT 3. OPERATION 3.1 CONTROL KEYS & INDICATORS 3.2 OPERATION MENU 3.3 OPERATION SETTINGS & STATUS 3.4 SYSTEM CONFIGURATION GUIDES 4. ...
IMPORTANT SAFETY INFORMATION This manual contains basic installation, operation and maintenance instructions for BioSure Professional Water Disinfection System (WDS), model EOS7177-PQ. For additional guidance, consult BES BioSure Professional Customer Service or your local authorized dealer. Attention Installer: This Manual contains important information about the installation, operation and safe usage of this product.
Page 7
• Do NOT use or operate the unit with a damaged Power Supply or Power Plug. If the Power Supply or Power Plug Cord is damaged, it must be replaced by the manufacturer, authorized service agent, dealer, or similarly qualified person in order to avoid hazard.
Page 8
• If any of the above symptoms occurred, unplug the product immediately and return to the store where you purchased it for service and repair. Continued use of the product may cause a fire, electric shock or injury. CAUTION • All permanent electrical connections should be made by a qualified electrician. Follow all applicable electrical codes.
Page 9
• ALWAYS ensure all factory installed parts and components are re-installed properly and are in good condition after performing service, maintenance, or installation work. • NEVER use inappropriate tools, processes, or procedures. Damage to components of device can occur. • NEVER discard any loose parts received with device. They may be required for proper and safe installation and operation.
PRODUCT INFORMATION 1.1 PRODUCT DESCRIPTION BioSure Professional Water Disinfection System (WDS), model EOS7177-PQ is an automatic germicidal system designed to reduce microbial contaminants for water purification applications. These can include post-filtraiton water and waterlines sanitation treatment, which removes or reduces unwanted microbial contaminants in filtered water and waterlines, or alternatively providing ozonated sanitizing water for sanitation use, depending on the way of installation and configuration.
INSTALLATION 2.1. PRECAUTIONS BEFORE INSTALLATION If any parts are damaged, contact your supplier IMMEDIATELY. Do NOT install damaged parts. This device is designed and engineered for easy integration into existing water systems. However, having the following tools and supplies in hand will be greatly helpful to the installation: •...
Page 13
Other Important Information Observe these guidelines to ensure optimal device functions and performances. 1. Select a location for the unit so: - Mount the system after all water filtration processes. - Mount the system near but NOT above an electrical outlet. - It will be in an upright position.
2.2. INSTALLING THE UNIT • STEP 1. Connecting Cell Power Connect the Cell Power Plug to the Cell Power Socket on the Head. Match the anti-rotation notch and pin. • STEP 2. Mounting the Unit The unit is pre-assembled to a 120mm Mounting Bracket.
Page 15
NOTICE PLUMBING NOTE 1. Before connecting the fitting to the System Inlet, the plumbing to the unit must be flushed clear of all debris. 2. Note the flow direction. Connect appropriate size of tubing on the “WATER IN” and “WATER OUT” sides of the unit.* 3.
2. Plug the Power Adapter into the wall electricity outlet. 3. The Screen and LEDs on the controller (the Head) will light up, indicating the unit has power. 00 : 00 NOTICE Before connecting the unit to power supply, ensure all plumbing connections are secure and leak-free, from shut-off valve to outlet.
OPERATION 3.1 CONTROL KEYS & INDICATORS Control Keys Menu / Return OK / Enter - Enter or return to Menu - Save selection Selections as ESC - Display alternatives - Confirm selection - Select settings Current time Indicators Timer control indicator Blue LED Timer switch activated - the unit Flow control indicator...
3.2 OPERATION MENU Menu Operating Principle 1. Read text line 2. Make decision / Confirmation change Highlighted press or Blinking texts/symbol represents question Revise press press Menu Overview 00 : 00 Settings Life Check Timer Program Time Control Dosage Extension Frequency Schedule...
Settings Control Select switching controllers, flow-starting, timer-controlling or both (Combo) Dosage Select dosing levels, standard or boost with 50% increase You can extend ozone generation time after each usage to raise Extension ozone concentration in advance for the next use. Options include: 1.
Page 20
Configuring Controls Step 1. Enter MENU and then select Settings 12 : 01 Press MENU . Timer Select Settings and confirm with . Settings Life Check Step 2. Select Control and follow on-screen options to select desired setting Select Control and confirm with . To select desired setting from on-screen options use ...
Page 21
Configuring Programs Setting working schedule and operation frequency program for Timer and/or Combo control schemes. MENU Setting schedule Step 1. Enter MENU and then select Timer Timer Program 12 : 01 Press MENU . Timer Select Timer and confirm with . Settings Schedule Life Check Step 2.
Page 22
Configuring Programs Step 3. Set Frequency To select desired working frequency setting 12 : 01 from on-screen options use . Confirm with . Configuring Dosage MENU Step 1. Enter MENU and then select Settings Settings Dosage 12 : 01 Press MENU . Timer Select Settings ...
Configuring Extension Step 1. Enter MENU and then select Settings 12 : 01 Press MENU . Timer Select Settings and confirm with . Settings Life Check Step 2. Select Extension and follow on-screen MENU options to select desired setting Settings Extension Select Extension and confirm with . To select desired setting from on-screen instructions and options use ...
MAINTENANCE 4.1 EXPECTED CELL LIFE The replaceable cell cartridge is Slow/Quick Blinking Steady Solid ON designed to typically last 12-24 months depending on the way of application Detect an error Replace cell and usage hours. Hard water or high- mineral content water (TDS >300 ppm) can shorten the cell life.
Page 25
5. Revert the procedures with a new cartridge for replacement. Step 1. Step 2. Step 3. NOTICE Install or uninstall Lock-in position Electrolytic Ozone Water Disinfection System This professional germicidal system reduces microbial contaminants for commercial water purification applications. It is more effective than UV as it charges dissolved ozone into water allowing for both water and waterline sanitation.
TROUBLESHOOTING Use the following guide to self-check your problems before requesting repairs. If you come into a conclusion that problem has occurred, do NOT attempt to disassemble and repair the product yourself, but contact BES Group or your dealer for support. Sometimes suspected problem is remedied by disconnecting the power plug and then re-connecting it.
Page 27
Problem Possible Cause Corrective Action Alarm is ON generator cell Reconnect the cell cable.If it Slow blinking does not work, please contact disconnection or connection your maintenance person or failure detected when turning authorized service agency. on the unit. On-screen Display Error 02 Alarm is ON Power off the unit and power...
Equipment. Biotek Environmental Science Ltd. is not liable under this warranty for repairs or damages due to alterations, abuse, fire, flood, or acts of nature.