QUICK START | ASSEMBLED TRACKS PROGRAMMING DIAMOND SENSE REMOTE CONTROL It is not necessary to fix the Shuttle motor to the track for programming a channel to a Shuttle motor. First select Press LED moves Keep button Green LED Within the desired button 3x from 1...
® the strain relief or wall (only for Shuttle S/M) Setting the end limits of the FOREST SHUTTLE S/M/L/ Receiver ® Before setting the end limits, the RF remote or IR remote channel can be programmed. The stack back (adjusted open limit) can be set by remote or switch.
Page 5
FOREST SHUTTLE S/M/L RECEIVER ® SETTING MOTOR DIRECTION AND CLOSE LIMIT: The Shuttle detects automatically the motor direction. By pulling the master carrier(s) ® towards closed position first, the Shuttle will automatically learn that motor direction. The ® master carrier will travel automatically towards the closed position.
CONFIGURATION Use a pin to change settings in the configuration menu. Choose the setting you want to change (table below) and press the button that many times (corresponding with setting). Confirm the desired setting by pressing the button for 4 seconds until the led blinks 3 times and goes OFF.
Page 7
RESET END LIMITS (4): For resetting only the end limits: press button 4x. To confirm, press and hold once more for 4 seconds until the led blinks 3 times and goes OFF. When a Forest remote is programmed to the Shuttle , the end limits can also be reset by pressing 5 times the P button and 5 times the STOP ®...
To change this setting see page 6. Shuttle S / L PAGE Automation system (potential free output) 24Vdc power supply (Shuttle ® S and M only) power outlet...
CONFIGURATION MASTER – SLAVE FUNCTION The Forest Shuttle M Receiver can be configured as MASTER or SLAVE, requiring two motors. MASTER: the controlling motor. SLAVE: the MASTER following motor. MASTER – SLAVE FUNCTION 1 (NORMAL SHUTTLE M RECEIVER 5232000003): ®...
Page 10
MASTER – SLAVE FUNCTION 2 : In this master -slave function two Shuttle M motors drive a Forest Skylight System (FSS). Direction of rotation of both motors is opposite. The motors have no automatic declutch. INSTALLATION STEPS: Make sure your system is fully assembled and mounted on the ceiling or wall before you start installing the two motors.
® 2.5A slow fuse. Each Shuttle M Receiver must be protected with a 4A slow fuse. ® 56,8 78,4 18,1 10,7 56,8 SHUTTLE S 225 mm 77 mm 49 mm SHUTTLE M 270 mm 77 mm 49 mm SHUTTLE L...
Use the product only as intended. This product is not suitable for use in humid spaces such as bathrooms or outdoors. In order for the Forest Shuttle S/M/L Receiver to function correct and safe, the complete curtain track system must be assembled with original &...
Need help?
Do you have a question about the SHUTTLE S and is the answer not in the manual?
Questions and answers