Pro
Zone
I n t e l l i g e n t Z o n i n g
Zones
See table below.
Compatible Equipment
All panels operate with gas/electric systems, conventional heat
pumps and dual fuel heat pumps.
Equipment Selection
Selected using the PDMi3 plug-in programming/display
module. See table below.
Heating and Cooling Stages
See table below.
Compatible Thermostats
When gas/electric equipment is selected, heat/cool thermostats
are used in all zones. When heat pump equipment is selected,
a heat pump or heat/cool thermostat may be used in Zone1
and heat/cool thermostats are used in all other zones. Wireless
thermostats can be used with the optional plug in wireless
radio, ISMR2
Compatible Thermostat Types
Single stage, 24VAC powered or battery powered thermostats.
Or, wireless thermostats, Models T200WZ or T500WZ.
Compatible Dampers
The ProR80J-XX dampers with plug and play cables. Each
damper is supplied with a 25-foot cable.
Dampers per Zone
Multiple dampers may be used to configure a zone. The total
number of dampers that can be used depends on the VA
rating of the 24VAC transformer used. Up to six dampers can
be daisy chained to configure a zone.
Bypass Control
The panel can be used with traditional mechanical barometric
dampers or by adjusting the closed position limit on each zone
damper.
Optional Sensors
Discharge air (Model TS2) and outdoor air temperature sensor
(Model TS3 can be used. A pressure sensor (Model PS2) can be
used to monitor duct pressure.
Zones on Panel
Expandable
Heating Stages
Cooling Stages
Compressor Stages
Auxiliary Heating Stages
PDM Display on Panel
Warranty
5-year warranty limited to repair or replacement of panel due to
defective material or workmanship.
ProC232J, ProC332J, ProC332JP and ProC300JX
Panel Power
24VAC (18 to 30), 10VA
Wiring
Use 18 or 20 AWG solid thermostat wire.
Humidity Rating
5 to 90% RH non-condensing.
Temperature Ratings
Shipping
Operating
Model ProC232J
Two
No
Two
Two
Two
One
No
Installation Guide
7-5/8 (193)
Zoning Panel
Fresh
PANEL
ZONE DAMPERS
THERMOSTATS
HVAC
Air
3
2
1
3
2
o
-20 to 150 F (-29 to 66 C)
o
o
0 to 165 F (-32 to 74 C)
Model ProC332J
Three
Yes. Up to 6 zones.
Gas/Electric Equipment
Two
Two
Heat Pump Equipment
Two
One
No
Rev F Jun 2015
1
1-5/8 (41)
o
o
o
o
o
Model ProC332JP
Three
Yes. Up to 6 zones.
Two
Two
Two
One
Yes

Advertisement

loading
Need help?

Need help?

Do you have a question about the ProC232J and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Prozone ProC232J

  • Page 1 Zone Installation Guide I n t e l l i g e n t Z o n i n g ProC232J, ProC332J, ProC332JP and ProC300JX Rev F Jun 2015 Zones See table below. 7-5/8 (193) Compatible Equipment All panels operate with gas/electric systems, conventional heat Zoning Panel pumps and dual fuel heat pumps.
  • Page 2 Features ProC332J and ProC232J Zoning Panels Multi-color LEDs indicate equipment call status. Green for cooling call. Red for heating call. Yellow for fan call. Multi-color LEDs indicate zoning panel status. Blinks for staged call or Em Heat. Blinks green when operating normally.
  • Page 3 The table below shows the VA required configure a zone. for each zoning component including the ProR80J dampers. Maximum VA Typical VA ProZone Model A80-MJ Damper Actuator Modulating Position 24VAC, 2.2VA Panel Made in USA...
  • Page 4 Wiring Zone Thermostats Heat Pump Thermostats with Auxiliary Heating Heat/Cool thermostats can be used in all zones. A heat pump A heat pump thermostat should be used in Zone1 when heat thermostat can be used in Zone1 with heat pump equipment to pump equipment is selected.
  • Page 5 Heat Pump System with Auxiliary Heat Installing the Outdoor Temperature Sensor Conventional and dual fuel heat pumps are wired the same as The outdoor temperature sensor (TS3) should be placed in a shown below. The Auxiliary heat or Emergency heat on a shaded location and protected from rain or snow such as under conventional heat pump is an electric strip heater and a gas the eves of a home.
  • Page 6 Plenum To Zoning Panel Wiring the Discharge Air Temperature Sensor Connect the red and white thermostat wires to the LAT Sensor (TS2) terminals as shown below. To Panel Zoning Panel Zoning Panel From Duct Pressure +VDC +VDC Sensor (PS2) From Discharge Temperature Sensor (TS2) Terminal Function...
  • Page 7 W2/E Relay WIRELESS RADIO WIRELESS RADIO EXT PDMi EXT PDMi Model ProC300J Adder Panel. PDM Programming/Display Module ProZone ProC332J V201 MENU NEXT UP / YES CANCEL SAVE DOWN / NO Using the PDMi3 The PDMi3 plugs into the panel and reads all the panel settings and the allowable settings for the options.
  • Page 8: Installer Menu

    Options and Factory Settings, All Zoning Panels Option Selections Factory Settings Equipment Gas/Electric, conventional or dual fuel heat pumps. Gas/Electric Indoor Fan Mode Gas or electric. High DAT Limit 110 to 180 F 160 F Low DAT Limit 37 to 55 F 45 F Em Heat Control Zone1.
  • Page 9 Setting Equipment Options Press Yes to select fresh air control. Change Fresh Air Press No to continue. Access the Installer menu and select the menu below. Press Y to set equipment options. The options will be different based on the type of equipment selected.
  • Page 10: Bypass Control

    Important! Equipment Type Press Yes to select dual fuel heat pump The total of the zone sizes should always equal the total number DFHP or No to return to gas/electric equipment of zones. Press Up or Down to change the Compressor Change Zone Size Press Yes to change the zone sizes or...
  • Page 11 Bypass Using the Non-Calling Zone Dampers Staging Heating and Cooling Calls The non-calling zone dampers can be opened just enough to Staging is controlled by the number of zones calling for heating or keep the airflow in the calling zones from being too high or noisy. cooling and by a timer that monitors the amount of time a call has The PDMi3 can be used set the bypass position for each zone in been active.
  • Page 12 Staging Based on Call Timer Direct Entry of Minutes per Hour of Fresh Air Staging is controlled by the number of minutes heating or If the contractor has calculated the CFM for fresh air and sized cooling has been calling. The Timer monitors the continuous the damper to operate for a number of minutes each hour, the call time and forces staging when the call time exceeds the minutes can be directly entered.
  • Page 13 Limit Fresh Air Based on Outdoor Temperature Changing Advanced Options Fresh air operation can be disabled if the outdoor temperature Press Yes to select advanced options Change Advanced exceeds the high and low temperature limits. A TS3 outdoor Options such as purge, opposite system service, temperature sensor is required.
  • Page 14: Testing The Installation

    Start Htg Test Press Yes to start a test of the This option determines whether all Dmprs Open heating system to insure discharge In Cont Fan Y/N zone dampers open in a continuous temperature is correct. fan call or only those zones calling for continuous fan.
  • Page 15 Monitor HVAC Press Yes to display the leaving air Performance Y/N temperature, duct pressure and the position of the non-calling zone dampers when used for bypass. Press No to continue. LAT 122 Prs 0.55 Displays the leaving air BP Pos 35% NEXT temperature, duct pressure and the position of the non-calling zone dampers when used for...
  • Page 16: Limited 5-Year Warranty

    Limited 5-Year Warranty ProZone The 5-year warranty is limited to the repair or replacement of 26072 Merit Circle #110 / Laguna Hills, CA 92653 defective product due to parts failure or defective workmanship. 949-916-0945 Fax 949-458-8502 www.ProZone-US.com...

This manual is also suitable for:

Proc332jProc332jpProc300jx