Summary of Contents for Flintec FAA-28

  • Page 1 FAA-28 Analog Amplifier Technical Manual Flintec GmbH Bemannsbruch 9 74909 Meckesheim GERMANY www.flintec.com...
  • Page 2: Table Of Contents

    Adjustment by Measuring the Analog Output .............16 Operation Mode ..................... 17 Programming With xFace Software Over RS232 ........18 Installation of xFace Software ................18 xFace Software ......................18 Trouble Shooting ................... 20 FAA-28, Technical Manual, Rev.1.1.0 February 2022 Page 1 of 21...
  • Page 3: Safety Instructions

    FLINTEC reserves the right to revise this manual and alter its content without notification at any time. Neither FLINTEC nor its affiliates shall be liable to the purchaser of this product or third parties for damages, losses, costs, or expenses incurred by purchaser or third parties as a result of: accident, misuse, or abuse of this product or unauthorized modifications, repairs, or alterations to this product, or failure to strictly comply with FLINTEC operating and maintenance instructions.
  • Page 4: Front View, Features And Specifications

    PLC and for changing the instrument without recalibration in service. There are 8 positioned rotary switches and annunciator LEDs in front of the instrument. The front view and pin descriptions of FAA-28 is shown below. Pin Name Definition...
  • Page 5 • Calibration at PLC does not require readjustment after changing instrument because of matching in the production. • 1 zeroing input and 2 free relay contact outputs for alarm or controlling valves, gate etc. FAA-28, Technical Manual, Rev.1.1.0 February 2022 Page 4 of 21...
  • Page 6 Operation Temperature -15°C … +55°C at 85% RH max, non-condensing EMC Immunity Class E2 Enclosure Polyamide, for DIN-rail mount, IP20 Dimensions Front Width:22,5 mm, Front Length: 99 mm , Height:114,5mm FAA-28, Technical Manual, Rev.1.1.0 February 2022 Page 5 of 21...
  • Page 7: Installation And Commissioning

    All external cables should be installed safely to avoid mechanical damages. FAA-28 instruments are very low level signal measuring instruments. To avoid electrical noise, FAA-28 should be separated from the equipments that produce electrical noise. Preferable use metal cabinet against radio frequency interference and the cabinet shall be connected to ground against the electromagnetic disturbances.
  • Page 8: Mechanical Installation

    + Excitation + Sense Short circuit to + Excitation - Excitation Short circuit to - Excitation - Sense - Excitation + Signal + Signal - Signal - Signal Shield Shield FAA-28, Technical Manual, Rev.1.1.0 February 2022 Page 7 of 21...
  • Page 9: Analogue Output Connection

    Only one of the analog output types can be used at the same time and has to be selected in the setup type. Install the analog output measuring instrument for adjustment, e.g. multimeter. Pin Name Definition Current Output Voltage Output Shield Current output connection Voltage output connection FAA-28, Technical Manual, Rev.1.1.0 February 2022 Page 8 of 21...
  • Page 10: Changing The Analogue Output

    Changing the Analogue Output FAA-28 sets its analog output according to the table below at power on. Turn the programming switch and connect TxD and RxD pins as indicated in the table below before power on the instrument to set analog output type and its signal level.
  • Page 11: Adjustments

    • Connect the measurement instrument (Multimeter is recommended) to the analog output • Load the scale with a known load • The analog output value should be calculated for the applied load FAA-28, Technical Manual, Rev.1.1.0 February 2022 Page 10 of 21...
  • Page 12 The instrument saves 4 different adjustments in its memory for the voltage and current outputs and their ranges. Changing the analog output type it automatically set the adjustment to the output range used before. FAA-28, Technical Manual, Rev.1.1.0 February 2022 Page 11 of 21...
  • Page 13: Fast Adjustment To Nominal Output Range

    Due to the production process of FAA-28, eCal accuracy is very high. Adjustment with eCal is performed via RS232 port of the instrument and can be comfortable executed with xFace software.
  • Page 14: Adjustment (Ecal) With Plc

    FAA-28 can be electronically calibrated via RS232C serial interface by commands or by xFace software. If you want to use your own software to calibrate the FAA-28 from your PLC or PC, you may use the commands below. The yellow colored bytes are the data in the command and blue colored bytes are check sum in this document.
  • Page 15 Stop the eCal process Response: @011000000001EE 3. Digital Filter Setting: Command: @011000220001020000CA Set the Fast filter Command: @011000220001020001C9 Set to Medium filter Command: @011000220001020002C8 Set to Slow filter Response: @011000220001CC FAA-28, Technical Manual, Rev.1.1.0 February 2022 Page 14 of 21...
  • Page 16: Testing The Scale Performance

    Testing the Scale Performance You have to check the scale performance by testing the scale eccentricity, scale linearity at loading up to maximum loading value, repeatability etc. before using it. FAA-28, Technical Manual, Rev.1.1.0 February 2022 Page 15 of 21...
  • Page 17: Setpoints

    5. Setpoints Setpoint Connection FAA-28 has 2 free relay contact output. These outputs can be connected to maximum 230VAC or maximum 30VDC, maximum 1A loads. Reverse diode connection to the DC loads is recommended to increase the relay contact life and to reduce the disturbances.
  • Page 18: Operation Mode

    6. Operation Mode There are 3 LEDs and 2 rotary switches on the front panel of FAA-28. The rotary switches are being used for adjustment as described in chapter 4.4 and the LEDs have different meanings in operation and setup type as indicated below.
  • Page 19: Programming With Xface Software Over Rs232

    7. Programming With xFace Software Over RS232 FAA-28 has RS232C serial interface to perform eCal electronic calibration and to adjust filter, setpoint values and to follow status by using xFace software installed on a PC. For installing the xFace software, which is supplied with the instrument or can be downloaded from www.flintec.com, follow the steps described below.
  • Page 20 12. Power on the instrument for operation. After performing eCal as described in the software, check the performance of your system. You may adjust to instrument to factory default by xFace, if it is changed before. FAA-28, Technical Manual, Rev.1.1.0 February 2022 Page 19 of 21...
  • Page 21: Trouble Shooting

    8. Trouble Shooting The type FAA-28 amplifier is designed as a very reliable and virtually error free instrument. However, if an error occurs, do not attempt to repair the equipment before you understand what caused the error. Note the status of the front panel LEDs, and try to find the problem with the help of the table given below.
  • Page 22 Flintec GmbH Bemannsbruch 9 74909 Meckesheim GERMANY www.flintec.com FAA-28, Technical Manual, Rev.1.1.0 February 2022 Page 21 of 21...