How to mount standard optional items (PDM-4001)
9) Power supply requirements
When it consists of some multiple systems, never provide the power from the existing
power outlet because it is extremely dangerous to do so. Make sure to provide the power
from the distribution panel.
1 Power voltage
Guaranteed operating voltage for a plasma display is +/-10% of the rated voltage. It is necessary to have a power
voltage of more than 100V (102 V to 105 V) without any load.
Ensure that the voltage will not drop below 96 V, when all the power has been turned ON.
If it drops below 96 V, it may be necessary to replace the power cable from the distribution panel to the plasma
display with a thicker one.
2 Calculate the power consumption of a plasma display at 400 VA per unit, to be on the safe side. When it is going to
be connected with any other equipment, take the power consumption of such other equipment into consideration.
When the total current capacity is obtained, make sure to derive the power from the power distribution panel
though a circuit breaker, allowing for about 25% or more extra power.
In Japan, it is customary to use 15 A to 20 A per circuit. If the total power consumption is higher than this, it is
necessary to increase the number of circuits, say, by two or three additional circuits.
No. of surfaces
of a plasma display unit
1 surface
4 surfaces
9 surfaces
12 surfaces
16 surfaces
Moreover, when the power for a plasma display is ON, the inrush current is about 70A. If it is composed of some
multiple systems, make sure not to turn ON all the systems at one time, but to turn ON one system after another.
If all the systems are turned ON at one time, the circuit breaker may be tripped.
3 Power supply breaker
To reduce the noise, the plasma display has a built-in power line filter. For this reason, a leakage current of 0.5 mA
is passing throughout the circuit. In case that a leakage breaker is provided, confirm that the leakage current sensivity
is greater than the leakage current value of the plasma display to be used.
10) Cautions for using base plates and cradles
Make sure to install so that the system remains horizontal. We will not be responsible in
any way whatsoever for any damages due to defective installation and/or mounting of
this system, or any natural disasters.
120
Power capacity
400VA
1600VA
3600VA
4800VA
6400VA
Current capacity
4A
16A
36A
48A
64A

Advertisement