Temperature and Humidity
data logger Manual
1-Product overview:
1. Sensor
2. Alarm indicator, red/green LED inside.
: green LED flashing,
:Red LED flashing.
3. Electronic function key
4. Mechanical switch, hold down the switch,
then pull out the shell.
5. USB protecting hood. Connect PC software,
then you can setting up the data logger.
2-Replace battery
Hold down the switch,
then pull out the shell.
Third step:
After Setting
"Manual" mode
Waiting start
Fourth step: After recording some data, you can use the PC software download data.
Sample rate is 1minute, 10 minutes is ten data.
4-Sample rate & Record time
Record time
Sample rate
/min
/day
1
13.9
2
27.8
3
41.7
55.6
4
5
69.5
6
83.4
97.3
7
Zi-9530
1
2
3
4
5
CR2450 Battery
Long Press
Recording
Record time
Sample rate
/min
/day
8
111.2
125.1
9
10
139.0
15
208.4
20
277.9
25
347.4
375.2
27
3-Simple start:
① Check the battery indicator
is normal.
② Connect the USB data logger to the Windows PC. The first time using, according to the computer
instructions, install the system's own driver. Similar to A new U disk.
③ Setting the data logger. Please check the software CD, use the PC software setting the data
logger. For more information, please refer to the PC software help document.
④ Recording and download data.
First step: Open the software. Then open the setting window.
Second step: refer to the picture.
*Logger Name will synchronize to the PDF reports.
*Enable high and low alarm parameter will synchronize to the PDF reports.
5-LCD display and button
Display:
①... Alarm indicator
②... Battery indicator
1
③... Record indicator
④... Humidity unit
⑤... Humidity reading
8
⑥... Temperature unit
⑦... Temperature reading
⑧... Function indicator
Buttons:
1
① Down key
② Replace battery
③ Enter key
• Alarm indicator
Measurement values are within programmed limits. Green LED is flashing.
Measurement exceeded the programmed limits. If activated during programming a red LED
is flashing.
• Battery indicator
Full battery
Battery OK
Low battery
Empty battery, replace
• Recording indicators
The current state of the recording is indicated by the following symbols:
Waiting start
Recording stopped
Recording started
Appear after setting
2
3
4
5
6
7
2
3