About the product

▶ Point out the possible consequences
(personal injury, including danger to
life or material damage) of non-
existent or improper inspection,
cleaning and maintenance.
▶ Leave the installation instructions and
the operating instructions with the
user for safekeeping.
H Damage caused by frost
The system can freeze if it is switched
off:
▶ Observe the notices regarding frost
protection.
▶ Due to the additional functions, e.g.
DHW heating or pump anti-seizure
protection, the system should always
be left on.
▶ Have faults rectified immediately.
2
About the product
The module is used to control the activation of a swimming
pool in conjunction with a heat pump with an EMS 2/EMS
plus interface. The heating circuit for the swimming pool is
heated directly by the heat pump via a mixer, and is
installed upstream of a buffer cylinder or a hydraulic
separator.
The module is used to determine the swimming pool
temperature and activate a mixer as required by the heat
pump.
Anti-seizing function: the connected mixing valve motor is
monitored and brought into operation automatically for a
short period after 24 hours of downtime. This prevents the
mixer from seizing up.
A maximum of one MP 100 is permitted in a system,
irrespective of the number of other BUS nodes.
11
2.1

Scope of delivery

Fig. 1 at end of document:
[1] Module
[2] Bag with installation accessories
[3] Swimming pool temperature sensor TC1 installation set
[4] Installation manual
2.2

Technical Data

This product conforms to European directives and
supplementary national requirements in design and
operation. Compliance is demonstrated by the CE
marking.
You can request the conformity declaration of the product.
If you require this, contact the address on the back cover of
these instructions.
Technical Data
Dimensions (W × H × D)
Maximum conductor cross-
section
230 V terminal
Extra-low voltage terminal
Rated voltages
BUS
Module mains voltage
User interface
Mixer
Fuse
BUS interface
Power consumption – Standby < 1 W
Max. power output
per connection(VC1)
Temperature sensor
measuring range
Lower fault limit
Display range
Upper fault limit
Permitted ambient
temperature
151 × 184 × 61 mm
(for more dimensions
 Fig. 2 at end of
document)
2
2.5 mm
2
1.5 mm
15 V DC
(reverse polarity
protected)
230 V AC, 50 Hz
15 V DC
(reverse polarity
protected)
230 V AC, 50 Hz
230 V, 5 AT
EMS 2/EMS plus
100 W
< – 10 °C
0 ... 100 °C
> 125 °C
0 ... 60 °C
MP 100 – 6721819201 (2020/02)