Parameters; Model Details; Regular Parameters; Frequency Range And Channels - Ebyte E92-DTU User Manual

Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.

4 Parameters

4.1 Model details

Model
E92-DTU(2G4HD12)
★Test range conditions: sunny and clear sky, test environment is open without obstruction, 12V/1A power supply, the
device is 2 meters above the ground, and the default parameters are used.

4.2 Regular parameters

No.
1
Product Size
2
Product Weight
3
temperature
4
Voltage range
Communication
5
6

4.3 Frequency range and Channels

Mode
E92-DTU(2G4HD12)
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
Freq.
TX Power
Test range
Hz
dBm
2.4G
12
1200
Name
Value
228*228*68 mm
1700g
Operating
-40℃~+85℃
8~28V DC
RS485
Interface
Baud rate
Default 9600
Main Freq.
Hz
2.4G
feature
m
Point-to-point frequency hopping
Bidirectional continuous transmission
Range
Hz
2.4~2.48G
E92-DTU(2G4HD12) User Manual
Application features
Suitable for environments
with long communication
distances and susceptible to
Description
See installation dimensions for details
Meet the need of industrial use
Recommend to use 12V or 24V
3.81 Terminal block
Baud rate range 1200~3M
Channel Width
Hz
1M
80(full duplex)
interference
Channels
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

2g4hd12

Table of Contents