3. Start two serial port debugging assistants, connect two RS485 network bridges respectively, select the default serial
port baud rate of 9600bps, and the check method is 8N1, open the serial port, and the serial port transparent transmission
can be realized.
4. If the customer needs to modify the parameters, please disassemble the RS485 bridge, switch the module inside to the
configuration mode and connect to the computer, open the E92-DTU(HD) RS485 bridge configuration software, you can
modify the relevant parameters and complete the configuration. The DIP switch status must be restored before
communication can be carried out.
Configuration Mode
Transceiving Mode
5