FAULTS
The following Fault messages are displayed
and logged in the banner during the fault
condition and then sent to the Cloud Server.
ID TEMP SENSOR HIGH
ID TEMP SENSOR LOW
REMOTE SENSOR HIGH
REMOTE SENSOR LOW
HUM TEMP SENSOR HIGH
HUM TEMP SENSOR LOW
ID TEMP RANGE HIGH
ID TEMP RANGE LOW
HUM SENSOR FAILURE
HUMIDITY RANGE HIGH
HUMIDITY RANGE LOW
OUTDOOR SENSOR FAILURE
Wi-Fi HARDWARE FAULT
Temperature reading > 122°F
• Temperature reading = 0
• Reading not available
Remote temperature > 122°F
NOTE Displayed only if REMOTE SENSOR is set to INDOOR or AVERAGE
Remote temperature = 0
NOTE Displayed only if REMOTE SENSOR is set to INDOOR or AVERAGE
Humidity sensor temperature > 122°F
NOTE Displayed only if using humidity temperature as a backup source during a fault condition with
the primary temperature sensor.
Humidity sensor temperature = 0
NOTE Displayed only if using humidity temperature as a backup source during a fault condition with
the primary temperature sensor.
Indoor temperature is > 99.0°F
Indoor temperature is < 40.0°F
Any of the following:
• Humidity sensor timed out
• Humidity reading is > 99%
• Humidity reading is 0
Humidity reading is > 90%
Humidity reading is < 10%
OD temp > 127 or < -60
Communications error occurred with Wi-Fi module (resets after valid message received)