Download Print this page

Samsung MWR-SH11UN Installation Manual page 16

Wired remote controller
Hide thumbs Also See for MWR-SH11UN:

Advertisement

Wired remote controller installation/service mode
Additional functions of your wired remote controller
• If communication initialization is needed after the setting, the system will reset automatically and
communication will be initialized.
NOTE
Main
Sub
menu
menu
Wired remote
controller
1
setting/
checking (1)
Wired remote
controller
2
setting/
checking (2)
1
Room
temperature
5
compensation
2)*
Number of
6
connected
units
Temperature increment/decrement unit
7
(°C only)
0
Factory option setting
1
2
2
1
2
3
Indoor unit
address/
4
4
option setting/
checking 3)*
5
6
7
Function description
Cooling/Heating selection
Use of wireless remote controller
for indoor unit
Main/Sub wired remote
controller
Temperature unit
Temperature sensor selection
Use of average temperature
Use of Auto mode
Temperature display
Temperature control reference
Temperature compensation value -9.9 ~ 9.9 °C
Number of indoor units
Software code
Software version
Target address setting
Main address setting/checking
RMC address setting/checking
Basic option setting/checking
Install option setting/checking
Install(2) option setting/checking Option code
MCU/Port address setting
ENGLISH-16
Setting value
Value
Factory default
0 - Cooling/Heating,
1 - Cooling only
0 - No use, 1 - Use
0 - Main, 1 - Sub
0 - Celsius(°C),
1 - Fahrenheit(°F)
0 - Indoor unit,
1-Wired remote
controller
0 - No use, 1 - Use
0 - No use, 1 - Use
0 - Set temperature
1 - Room
temperature
2 - Relative
temperature 1)*
Current sensor
-9 ~ 40 °C
temperature
0 ~ 16
0 - 1 °C, 1 - 0.5 °C, 2 -
0.1 °C
0 - Unchanged,
1 - Factory setting
Software code
Software version
Target address of
indoor unit (Example
View master
: 20 02 1F)
0~4F (in hexadecimal
Main address of
digits)
RMC address of
0x00~0xFE 4)*
Basic option
Option code
of target
Install option of
Option code
Install(2) option
of target
MCU address (00 to 15)
MCU address of
Port address (A to F)
Page
Save location
0
01
Wired remote controller
1
02
Wired remote controller
0
03
Wired remote controller
0
04
Wired remote controller
0
01
Wired remote controller
0
02
Wired remote controller
1
03
Wired remote controller
0
04
Wired remote controller
01
Wired remote controller
0
02,03 Wired remote controller
0
01
None
0
01
Wired remote controller
0
01
None
None
01~03
None
None
01~03
None
01~03
None
01
None
target
01
None
target
01~20
None
5)*
01~20
None
target
5)*
01~20
None
5)*
01~02
None
target

Advertisement

loading