Operating and installation instructions Control unit Type GRANUDOS S5 without dosing unit GRANUDOS 45/100-S5 + GRANUDOS 10-S5 GRANUDOS 15-S5 Operating instructions for the dosing unit: Operating instructions for the dosing unit: GRANUDOS 45/100 GRANUDOS 10 No.: BA SW 003 No.: BA SW 002 GRANUDOS 15 No.: BA SW 002...
Reproduction of any kind and translation into other languages, even in excerpts, are only permitted with the express authorisation of the company WDT - Werner Dosiertechnik GmbH & Co. KG. These operating instructions are an English translation of the original German version by the company WDT. Responsible for the content: Co.
GRANUDOS S5, control unit About these instructions / general Scope of applicability This manual describes the function, installation, commissioning and operation of the device. Read these operating instructions carefully prior to operating the device and keep them in close proximity to the device for immediate use! Target group Only our authorised partners and people who have been trained in the device functions are permitted to...
All WDT devices and equipment are manufactured using modern production methods and are subject to comprehensive quality control. However, should there be a reason for complaint, any compensation claims shall be directed to the company WDT in accordance with the general terms and conditions of warranty (see below).
GRANUDOS S5, control unit Safety Intended use The GRANUDOS S5 control unit must only be used for the purposes described in the Product Description in Chapter 3.2, Product description! The locally applicable regulations concerning accident prevention, occupational safety and drinking water protection must also be observed! Safety notices Carefully read and comply with the operating instructions prior to installation, maintenance and use of the device!
The GRANUDOS S5 control unit is mounted on the respective dosing device. Figure 1, GRANUDOS 45/100-S5 + 15-S5 Figure 2, GRANUDOS 10-S5 GRANUDOS S5 control unit The control unit is contained in a dust-proof housing. The home screen, called “automatic” operation in the display, shows the operation mode, the dosing performance and any pending actions or fault indications, if applicable.
See the dosing unit of the respective dosing device. Commissioning For commissioning, see the operating instructions for the dosing unit of the respective dosing device. for Granudos 10-S5 + 15-S5, No.: BA SW 002 for Granudos 45/100-S5, No.: BA SW 003 The mechanical commissioning is completed.
GRANUDOS S5, control unit Operation / service of the control unit Operation of the display GRANUDOS S5 The operation modes and faults are displayed directly on the start screen (operation display): see 6.2, Figure In automatic operation, the current operation mode, the control, the set dosing performance, output for chlorine or pH dosing and any potential delays or faults are displayed.
GRANUDOS S5, control unit Start screen – Automatic The device is in the Automatic operation mode. The device doses upon request via an external controller. The set dosing performance is displayed. There is no fault. Notice! The dosing stops once you switch to the main menu by touching “Enter” and only starts again once you switch back to the operation mode.
Page 10
GRANUDOS S5, control unit Start screen – Fault indication – Acknowledge alarm If a fault occurs, this will be indicated by a red display and the fault indication in the bottom line. For a description of the fault indications, see Chapter Fehler! Verweisquelle konnte nicht gefunden werden., Fehler! Verweisquelle konnte nicht gefunden werden..
GRANUDOS S5, control unit Main menu Settings (overview) The Settings menu is used to implement the desired settings for the dosing device. Use the arrow keys to navigate to the next menu item. Dos perform. Adjust dosing performances for chlorine and acid with monitoring to the pool size Shock chl.
Page 12
GRANUDOS S5, control unit Explanation of the setting parameters Chlorine: Dosing time for chlorine granulate in seconds per cycle, can be set from 1-15 sec. The dosing performance set in this way can be seen on the start screen. It is best to use the “shortcut”, see Chapter 6.1.
Page 13
(e.g., hydrochloric acid, dissolved sodium bisulphate, etc.), the changed dosing performance and/or increased corrosiveness must be observed! We recommend consultation with the company WDT! NOTICE! When refilling the pool, the pH value must be manually brought to the desired value, since a relatively large amount of acid is required to reach the desired value with a high pH value and extreme hardness.
Page 14
GRANUDOS S5, control unit If a wrong password is entered, the display colour changes to red, and the password must be re-entered. Only certain predefined menu areas require a password to be entered. The password is automatically queried in these areas. The respective areas are: ...
Page 15
GRANUDOS S5, control unit Main menu Settings Config. Cl (chlorine dosing performance) (password entry) This setting can only be executed by entering the password. DS denotes dosing screw Here, the dosing components: dosing motors, dosing screws that can be used are displayed.
Page 16
GRANUDOS S5, control unit Maximum achievable dosing performance, depending on the dosing pump’s hose diameter. Hose kit - hose diameter maximum dosing performance* 0.8mm 100 ml/h 1.6mm 400 ml/h 3.2mm 1200 ml/h 4.8mm 2400 ml/h * The specified values are the maximum dosing performance of the GRANUDOS; this represents 25% of the pump’s permanent dosing performance.
Page 17
GRANUDOS S5, control unit a) Frequency control pH external, Cl external The maximum number of impulses (frequency) of the external control technology is set on the GRANUDOS up to max. 200 impulses/minute. The GRANUDOS now always counts the incoming impulses per minute, calculates the requested dosing performance on this basis and doses the respective amount in the following cycle.
GRANUDOS S5, control unit Main menu Settings Input inverse (password entry) With an activation via an external control (e.g., central control technology CCT) it may be necessary to invert the input signals “CCT OFF” and “Dosing CCT OFF”. Here, you can switch between NC and NO.
GRANUDOS S5, control unit Main menu Service Output test The output test is used to check the connected outputs (actuators and relays). The selected output is activated for 20 seconds. The activation can be cancelled at any time using “Enter”. For safety reasons (generation of chlorine gas), the output test for the chemical-dosing outputs is only released if no fault exists that could prevent the dosing, e.g., flow in the suction pipe too low.
Tip! In order to carry out any maintenance work, use the maintenance protocol found in Chapter 9.5, of the respective dosing device: for Granudos 10-S5 + 15-S5, No.: BA SW 002 for Granudos 45/100-S5, No.: BA SW 003 Document all work in the maintenance protocol.
GRANUDOS S5, control unit Troubleshooting Tip! All faults and messages are displayed in the status line on the display. In addition, they may be queried in the Event log. An error will only be displayed once it has occurred uninterrupted for at least 6 seconds. Attention! In the event of a fault indication, it is also possible that switches or sensors are defective! No collective fault for chlorine / acid empty!
Page 22
GRANUDOS S5, control unit 7. Fuse F2 ALARM The fuse F2 has blown. The Renew the fuse and check whether all other fuses Secondary fuse 24V-500mA dosing and booster pump stop show the correct fuse value. If F2 fails again, exchange the circuit board 8.
GRANUDOS S5, control unit Decommissioning – Storage – Disposal See operating instructions for the dosing unit of the respective dosing device: for Granudos 10-S5 + 15-S5, No.: BA SW 002 for Granudos 45/100-S5, No.: BA SW 003 Documents...
GRANUDOS S5, control unit Wiring diagrams DANGER! Risk of death due to high voltage! Any work on the device may only be carried out by trained specialists in accordance with the applicable safety regulations! Internal fuses may only be renewed once the voltage has been disconnected and secured against being reactivated! Wiring diagram Network board GRANUDOS 45/100 Index: 02...
GRANUDOS S5, control unit Wiring diagram Network board GRANUDOS 10 + 15 Index: 02 Date modified: 11/05/2021 OI No.: BA SW 014-02 Granudos S5-Steuereinheit EN.docx Page 25 of 29...
Commissioning protocol The commissioning protocol can be found in the operating instructions for the dosing unit of the respective dosing device in Chapter: 9.3. for Granudos 10-S5 + 15-S5, No.: BA SW 002 for Granudos 45/100-S5, No.: BA SW 003 Operation data sheet During a “software update”, all parameters are reset to the ex-works setting.
Page 27
GRANUDOS S5, control unit Operation data sheet, --master copy-- Please copy the blank operation data sheet before filling it out! Optimised during op- Settings menu Ex works setting Setting ranges Step during commissioning eration 1. Chlorine/pH dosing Date: Date: performance Chlorine 15 seconds 1-15 seconds...
Maintenance protocol The maintenance protocol can be found in the operating instructions for the dosing unit of the respective dosing device in Chapter 9.5. for Granudos 10-S5 + 15-S5, No.: BA SW 002 for Granudos 45/100-S5, No.: BA SW 003 Spare parts list, wear parts list, consumables The spare parts and wear parts listed in the following are available through your specialist dealer.
GRANUDOS S5, control unit 10.1 Menu overview Operation Display GRANUDOS Dosing Event Log Automatic Reset alarm Settings Service ON / OFF ON / OFF display / delete chlorine Dosing Cycle Input test performance Dos-limit CL Dos-limit pH Shock Qutput test clorination Shock chloring Cl Shock chloring pH...