Nemic-Lambda ZUP Series Manual page 7

Programmable regulatedpower supplies
Table of Contents

Advertisement

SAFETY INSTRUCTIONS
CAUTION
The following safety precaution must be observed during all phases of operation, service and repair of
this equipment. Failure to comply with the safety precautions or warnings in this document violates
safety standards of design, manufacture and intended use of this equipment and may impair the built-in
protections within.
Nemic-Lambda shall not be liable for user's failure to comply with these requirements.
INSTALLATION CATEGORY
The ZUP Series has been evaluated to INSTALLATION CATEGORY II. Installation Category (over
voltage category) II: local level, appliances, portable equipment etc.. With smaller transient over
voltages than Installation Category (over voltage category) III.
GROUNDING
This product is a Safety Class 1 instrument. To minimize shock hazard, the instrument chassis must be
connected to an electrical ground. The instrument must be connected to the AC power supply mains
through a three conductor power cable, with the ground wire firmly connected to an electrical ground
(safety ground) at the power outlet.
For instruments designed to be hard - wired to the supply mains, the protective earth terminal must be
connected to the safety electrical ground before an other connection is made. Any interruption of the
protective ground conductor, or disconnection of the protective earth terminal will cause a potential
shock hazard that might cause personal injury.
FUSES
Fuse must be changed by authorized Nemic-Lambda service personnel only. For continued protection
against risk of fire, replace only with the same type and rating of fuse. Refer to maintenance instructions
in chapter 6 for fuse rating.
INPUT RATINGS
Do not use AC supply which exceeds the input voltage and frequency rating of this instrument. The
input voltage and frequency rating of the ZUP Series is; 100-240V~, 50/60Hz. For safety reasons, the
mains supply voltage fluctuations should not exceed +/- 10% of nominal voltage.
LIVE CIRCUITS
Operating personnel must not remove the instrument cover. No internal adjustment or component
replacement is allowed by non-Nemic-Lambda qualified service personnel. Never replace
components with power cable connected. To avoid injuries, always disconnect power, discharge
circuits and remove external voltage sources before touching components.
PART SUBSTITUTIONS & MODIFICATIONS
Part substitutions and modifications are allowed by authorized Nemic-Lambda service personnel only.
For repairs or modifications, the instrument must be returned to a Nemic-Lambda service facility.
ENVIRONMENTAL CONDITIONS
The ZUP series safety approval applies to the following operating conditions:
* Indoor use
* Maximum relative humidity: 90% (no dew drop)
* Pollution degree 2
* Ambient temperature: 0 C to 50 C
* Altitude: up to 3,000 m