3.8.2 Pin Description
#
Name
Description
Resistive Constant Voltage programming
1
RCVP
Resistive Constant Current programming
2
RCCP
Reference voltage for Constant Current control. (connected to
3
VRFI
VCCP pin except external voltage or resistive programming).
Input of the Constant Current control circuit.
4
VCCP
Reference voltage for Constant Voltage control. (connected to
5
VRFV
VCVP pin except external voltage or resistive programming).
Input of the Constant Voltage control circuit.
6
VCVP
Open collector output. 0~0.8V during normal operation, open at
7
OUTPUT
GOOD
fault condition (OVP, FOLD and Over-Temp.).
Parallel connection pin.
8
P
On/Off control pin.
9
ON/OFF
Common pin for programming, On/off control and Output Good
10
COM
signal. Internally connected to - Sense.
Positive Local sensing pin.
11
+ LS
Positive Sensing pin for remote sense operation.
12 + S
Negative Local sensing pin.
13
- LS
Negative Sensing pin for remote sense operation.
14
- S
Table 3-3: External Control connector pin description
COM pin (10) is connected internally to the - Sense potential. Connection of the COM to another
potential or other than shown in this manual may cause damage to the power supply.
3.8.3 External Control Connector - Technical description
1. Connector type : AMP, Part No: 5102617-5 14 contacts, double row.
2. Receptacle : AMP, Part No: 87631-9, Polarized, 14 contacts, double row.
3. Receptacle contacts : AMP, Part No: 87523-5 (strip form) or 87523-6 (loose piece).
4. Wires : AWG: 24 to 20.
5. Hand tool for wire connection : AMP, Part No: 90202-2.
6. Applicator for stripper/crimper machine : AMP, Part No: 466905-1
CAUTION
Par.
4.4.10
4.4.10
4.4.10, 11, 12
4.4.10, 11, 12
4.4.10, 11, 12
4.4.10, 11, 12
4.4.15
4.4.13
4.4.8
4.4.10, 11, 12
4.4.8
3.7.3, 4, 5, 6
3.7.3, 4, 5, 6
3.7.3, 4, 5, 6