Dell EMC VxFlex Ready Node 14G Inspection Manual page 7

Hide thumbs Also See for EMC VxFlex Ready Node 14G:

Advertisement

The rebuild of Disk 0 in Backplane 1 of Integrated RAID
l
Controller 1 failed due to errors on the source physical
disk.
A block on Disk 0 in Backplane 1 of Integrated RAID
l
Controller 1 was punctured by the controller.
If either of these alerts appears in the system event log, one of the disks on the
SDS may have failed and requires replacement. Refer to the relevant VxFlex
Ready Node v2.x Disk Replace FRU Guide . In order to avoid data loss or data
integrity issues, follow any additional instructions for replacing a disk when
either of these errors occurs.
6. Ensure that any power supply- and fan-related events in the event log are non-
repetitive. Repetitive events may be due to the intermittent nature of faults,
such as poor physical connections.
For repetitive events, it is recommended that you remove the relevant hardware
module and replace it in its socket.
7. In the navigation pane, select Storage
A table displays the controller-related information, with the controller type in
the Name column. For example:
ESXi: PERC H740P Mini (Embedded)
l
Linux: PERC H740P Mini (Embedded)
l
Windows: PERC H740P Adapter (PCI Slot 4)
l
8. In the navigation pane, select Storage
A table displays information regarding the physical disks, and an option to
Blink/Unblink the selected disk.
9. Verify that no disk is in failed state.
If any of the disks is failed, refer to the relevant Disk Replace FRU.
10. In the navigation pane, select System.
11. In the Inventory pane, verify that the server drivers and firmware in the
Firmware Inventory list match the required versions, as published in the
ScaleIO Ready Node Driver and Firmware
If the driver and firmware versions do not match the matrix, you must update
them. See "Updating the BIOS, firmware and settings" in the VxFlex Ready Node
Hardware Configuration and Operating System Installation Guide for the relevant
operating system.
Verify the status of the system hardware, storage controller, and disks
Server Inspection Guide
Overview
Controller.
>
>
Physical Disks.
>
Matrix.
7