Maintenance - Whirlpool AGB 448/WP Installation, Operating And Maintenance Instructions For The Installer And The User

Gas pasta cooker
Table of Contents

Advertisement

Checking the pilot light
When correctly adjusted, the pilot light flame will com-
pletely surround the thermocouple and will not flicker; ;
if it does, adjust the pilot flame as described in para-
graph "Pilot burner adjustment".
Checking the primary air
The appliance can be adjusted. Air volume flow is cor-
rect when there is sufficient protection against the fla-
me rising when the burner is cold or light-back when it
is hot. Position the ring at measurement "A" (Fig. 1) in-
dicated in table 1 for type of gas.
Checking the functions
- Start the appliance in accordance with the instructions;
- Check the gas tubes for leaks;
- Check that the flame on the main burner lights
properly and is correctly formed, even on low;
- Check that the pilot light is correctly regulated;
- Draw up a servicing and maintenance contract.
Note for the installer
- Explain and demonstrate to the user how the machi-
ne works according to the instructions, and hand him
this manual.
- Remind the user that any structural alterations to the
room housing the appliance may affect the combu-
stion air supply. Once the alterations have been com-
pleted, the appliance and its functions should be tho-
roughly checked.
Running the appliance on other types
of gas
When changing to another type of gas, e.g. from natural
to LP, or to another gas group, consult the "TECHNICAL
DATA" table to determine the correct nozzles to use.
The nozzles for the main burners and pilot light for diffe-
rent types of gas, marked in 100ths of mm, are in a ca-
se supplied with the appliance.
When the appliance has been transformed or adapted,
recheck its functions as described in paragraph
"Checking the functions".
013 - 03 - Gas pasta cooker
Replacing the main burner nozzle
To change nozzle (30), open the doors. Unscrew the
nozzle from the nozzle holder using a 12 spanner; repla-
ce with a new nozzle (see "TECHNICAL DATA" table).
If necessary, to make changing the nozzle easier, loo-
sen screws (39) to remove the air adjustment sleeve.
Pilot burner adjustment (Fig. 2)
The pilot burner is easily accessible once the doors ha-
ve been opened.
Remove screw (35) and adjust the flame with a screw-
driver. Once adjusted, replace and tighten screw (35)
inserting the relative gasket.
The pilot flame is correctly adjusted when it completely sur-
rounds the thermocouple and safely lights the main burner.
Adjusting the low flame (Fig. 3)
Referring to the "TECHNICAL DATA" table, set the low
flame screw (2) as follows:
- if the appliance is to run on LP gas, tighten the low
flame screw as far as it will go;
- if the appliance is to run on natural gas, turn the low
flame screw while simultaneously adjusting the pri-
mary air:
- read off the setting in It/min which corresponds to the
heat value (calculated by the "Volumetric Method") in
the Gas Flow Setting Table (2); start the appliance up
according to the instructions;
- after allowing the appliance to run for same mins.,
turn the knob to low and set minimum gas flow by tur-
ning screw (2) (to the right = gas flow decreases; to
the left = gas flow increases).

MAINTENANCE

The following maintenance programme should be car-
ried out at least once a year:
- Check that all the safety and setting devices are
working properly;
- Check that the burners are working properly with re-
gard to:
- ignition
- combustion safety;
- Check the functions of the appliance as described in
paragraph "Checking the functions" page 11.