Download Print this page

AEMC JM810A User Manual page 2

Ac current probe

Advertisement

ELECTRICAL SPECIFICATIONS
Current Range:
1 to 2000A
, continuous cycle for
AC
the full temperature range
Transformation Ratio:
2000:2
Output Signal:
1mA AC/A AC (2A at 1000A)
1.97 x 5.31" (50 x 135 mm) or
2.52 x 3.94" (64 x 100 mm)
4.72"
(120 mm)
Ø =2.52" (64 mm)
Cable max.
Bus Bar max.
1.89"
(48 mm)
Accuracy and Phase Shift*:
Primary current
Accuracy %
Phase shift
*(Reference conditions: 23°C ±3°C, 20 to 85%
RH, 48 to 65 Hz, external magnetic field < 40 A/m,
no DC component, no external current carrying
conductor, test sample centered.)
Load impedance 0.5Ω.
12.40"
(315 mm)
P1
P2
100A
400A
2%
1%
1.5°
0.75°
Black
Red
2000A
0.5%
0.5°

Advertisement

loading

This manual is also suitable for:

2110.80