General Information - Wolf Steel Continental Fireplace CDVS500P Installation And Operating Instructions Manual

Table of Contents

Advertisement

2.3

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION
AND QUALITY!
Altitude (FT)
Max. Input (BTU/HR)
Max. Output Steady State (BTU/HR)
Effi ciency (w/the fan on)
Maximum A.F.U.E.
Min. Inlet Gas Supply Pressure
Max. Inlet Gas Supply Pressure
Manifold Pressure (Under Flow
Conditions)
For elevations between 2,000 and 4,500 feet above sea level, this appliance must be de-rated by 10% using
the certifi ed high altitude kit. When the appliance is installed at elevations above 4,500ft, and in the absence
of specifi c recommendations from the local authority having jurisdiction, the certifi ed high altitude input rating
shall be reduced at the rate of 4% for each additional 1,000ft.
Change in fl ame appearance from "HI" to "LO" is more evident in natural gas than in propane. Expansion /
contraction noises during heating up and cooling down cycles are normal and to be expected.
CDVS500: This appliance is approved for bathroom, bedroom and
bed-sitting room installations and is suitable for mobile homes. The
natural gas model is suitable for installation in a mobile home that is
permanently positioned on its site and fueled with natural gas.
CS500: This appliance is approved for bedroom and bed-sitting room
installations.
CS500
NG
LP
0-2000
0-2000
44,000
40,000
31,200
30,000
77%
78%
65%
67%
4.5" Water
11" Water
Column
Column
7" Water
13" Water
Column
Column
3.5" Water
10" Water
Column
Column
CDVS500
NG
LP
0-2000
0-2000
44,000
40,000
37,000
34,400
84%
86%
77%
79%
4.5" Water
11" Water
Column
Column
7" Water
13" Water
Column
Column
3.5" Water
10" Water
Column
Column
70%
CDVS500
W415-0514 / E / 04.16.12
7

Advertisement

Table of Contents
loading