36
8.1

REPLACEMENT BLOWER INSTALLATION

THERMODISC
Turn off the electrical power and the gas supply to the appliance.
A.
Open the lower louvre control door, the two side doors and the fi re viewing door. Remove the logs.
B.
Remove the relief door assembly held on with 6 screws. Discard the gasket.
C.
Disconnect the two blower wires. Remove the blower bracket held on with 4 screws.
D.
Replace the blower using the existing bracket. When connecting the replacement blower, tighten
E.
the screws without distorting the rubber grommets. Replace the bracket / blower assembly in the
appliance.
Reconnect the two wires. Hold the replacement gasket in place and reattach the relief door assembly.
F.
Replace the logs. Close all doors.
Turn the gas supply and electricity back on.
G.
Because the blower is thermally activated, when turned on, it will automatically start approximately 15-
30 minutes after lighting the appliance and will run for approximately 30-45 minutes after the appliance
has been turned off. Use of the fan increases the output of heat.
Drywall dust will penetrate into the blower bearings causing irreparable damage and must be
prevented from coming into contact with the blower or its compartment. Any damage resulting from this
condition is not covered by the warranty policy.
W415-0514 / E / 04.16.12
VARIABLE
SPEED
SWITCH
RELIEF DOOR GASKET
RELIEF DOOR
TWIN BLOWER