Fujitsu PRIMERGY RX2530 M5 Operating Manual page 33

Hide thumbs Also See for PRIMERGY RX2530 M5:
Table of Contents

Advertisement

Pos. Label
Indicator
CSS
2
[CSS]
indicator
Global
Error
indicator,
see also
3
"iRMC-
related
status
signals" on
page 35
HDD/SSD
4
activity
indicator
Power-on
5
indicator
RX2530 M5
Status
Description
No critical event detected (CSS
off
component).
Prefailure event detected (CSS
component).
orange
For HDDs/SSDs, see also
on
"HDD/SSD prefailure detection" on
page
35.
flashing
CSS component failure detected.
orange
No critical event detected (non CSS
off
component).
orange
Prefailure event detected (non CSS
on
component).
Non CSS component failure
detected.
Possible causes:
– System is out of the specified
flashing
temperature range
orange
– Defective sensor
– CPU error
– Error detected by server
management software
flashing
Data access in progress.
green
off
The server is switched off.
– The server has been switched on
but Power Cycle Delay settings
delay it from turning on for a
green on
specified time.
– The server is switched on and
operating normally.
flashing
The BMC firmware is starting up after
green
the server has been connected to the
slowly
mains.
Operating Manual
Product description
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents