Adjusting projected images (continued)
Adjusting the color variations
You can adjust the variations in the colors of the
images displayed on multiple projectors using the
menu settings.
(See page 31 for menu setting.)
Adjustment while viewing the screen
1. Display the MULTI-SCREEN menu.
2. Select COLOR MATCHING by pressing the  or 
button.
COLOR MATCHING
3. Select MANUAL by pressing the  or  button.
4. Select MANUAL by pressing the  or  button.
MANUAL
by pressing the  or  button.
5. Select SETTING
6. Press the ENTER button.
MANUAL – SETTING
COLOR
GAIN
SATURATION
HUE
WHITE R
WHITE G
WHITE B
AUTO PATTERN
7. Select an item you want to set by pressing the  or
 button.
COLOR.
pattern of each color is displayed.
8. Select a setting value by pressing the  or 
button.
Repeat steps 7 to 8, if necessary.
Adjustment using a chroma meter
1. Display the MULTI-SCREEN menu.
2. Select COLOR MATCHING by pressing the  or 
button.
COLOR MATCHING
3. Select MEASURE by pressing the  or  button.
Set the measured brightness and the chromaticity
coordinates:
4. Select MEASURE by pressing the  or  button.
MEASURE
5. Select MEASURED DATA
button.
6. Press the ENTER button.
MEASURE – MEASURED DATA
COLOR
Y (RELATIVE)
x
y
OFF
SETTING
RED
0
0
0
- - -
- - -
- - -
ON
OFF
MEASURED DATA
by pressing the  or 
RED
*****
.
*
***
.
*
***
7. Select an item you want to set by pressing the  or
 button.
COLOR.
8. Select a setting value by pressing the  or 
button.
buttons (0 to 9) while holding down the NUM
button on the remote control.
Repeat steps 7 to 8, if necessary.
Important:
depending on the setting value. Set the value within
the proper range.
Set the target values of the brightness and
chromaticity coordinates:
4. Select MEASURE by pressing the  or  button.
MEASURE
5. Select TARGET DATA
button.
6. Press the ENTER button.
MEASURE – TARGET DATA
COLOR
GAIN
x
y
AUTO PATTERN
7. Select an item you want to set by pressing the  or
 button.
COLOR.
pattern of each color is displayed.
8. Select a setting value by pressing the  or 
button.
buttons (0 to 9) while holding down the NUM
button on the remote control.
Repeat steps 7 to 8, if necessary.
Important:
The color tone may not be displayed correctly
depending on the setting value. Set the value within
the proper range.
Resetting the settings
MEASURE settings to the factory defaults.
1. Display the MULTI-SCREEN menu.
2. Select SETTING, MANUAL or MEASURE by
pressing the  or  button.
3. Select RESET
4. Press the ENTER button.
EN-50
MEASURED DATA
by pressing the  or 
RED
.
*
***
.
*
***
.
*
***
ON
by pressing the  or  button.

Advertisement