• PIR-100
Standard
Nominal Range 120 m (400 feet)
• PIR-100H High Performance
Nominal Range 150 m (500 feet)
Page 1 (12)
Installation Manual
Long-Range Curtain
Version 2.0 and higher
06/2008

Highlights

• Gap-Free Coverage with Creep Zones
• 4 Meter (13 Feet) Mounting Height
• Advanced Tamper Detection
• Low Power Consumption – Ideal for Wireless and
• Wide Power Supply Range
• Heater & Heavy Duty Front Window (H version only)
• Integrated Bracket for Wall Mounting
• Remote Configuration and Alarm Management
Solar Applications
www.ernitec.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Eagle PIR-100 and is the answer not in the manual?

Questions and answers

Summary of Contents for ERNITEC Eagle PIR-100

  • Page 1: Standard Models

    Installation Manual Ernitec Eagle PIR-100 & 100H Long-Range Curtain Detectors for Perimeter Protection Outdoors Version 2.0 and higher 06/2008 Highlights • Gap-Free Coverage with Creep Zones • 4 Meter (13 Feet) Mounting Height • Advanced Tamper Detection Standard Models • Low Power Consumption – Ideal for Wireless and •...
  • Page 2 Page 2 (12) www.ernitec.com...
  • Page 3: Table Of Contents

    20 Appendix Two Way Communication RS 485 ................. 11 20.1 Introduction ..............................11 21 Appendix Installation Software ...................... 11 21.1 Introduction ..............................11 21.1.1 Application of the Installation Software ....................... 11 22 Appendix Specification ........................12 22.1 Mechanical Dimensions ..........................12 Page 3 (12) www.ernitec.com...
  • Page 4: Introduction

    Output logic and function can be changed using the installation software. During turn-on time the relay output is in alarm state! Cover Switch To detect attempts to open the detector, a switch is fitted for the cover. Its contact opens when the cover is opened. Page 4 (12) www.ernitec.com...
  • Page 5: Field Of View

    (see Fig. 2 below). Movement within the field of view will reduce the sensitivity of the PIR by increasing the alarm threshold level and may lead to unwanted alarms. Top view Fig. 2 Page 5 (12) www.ernitec.com...
  • Page 6: Sensitivity Settings For Range And Mounting Height

    If the Installation software is used for monitored walk tests and the DIP – Switches 1 and 2 are set to software settings (on – on), the threshold level can be kept to its nominal value by changing the configuration of the ATD to „off“ for this test. Page 6 (12) www.ernitec.com...
  • Page 7: Anti Vandal Function

    13 Internal Heater (H version only) A regulated heater connected to the electronic board and powered by the supply voltage of the PIR-100H prevents the optical surfaces from fogging or frosting and maintains the internal temperature at optimal levels. Page 7 (12) www.ernitec.com...
  • Page 8: External Sensitivity Adjustment Via Rs 485 Data Bus

    If more than one detector is connected to the same RS 485 communication bus, each detector needs to have a different address (ID). Please see the PIRIF-485/2 Installation and Setup Manual, for further details. 16.2 Pole Mount Hardware ZA P-L1 Pole mounting bracket with two strap bands for poles of 4 – 16 cm diameter Page 8 (12) www.ernitec.com...
  • Page 9: Maintenance

    • Any liability for direct or indirect damage resulting from the use of the PIR as a detection device is explicitly disclaimed. • The information in this product manual is based on testing of samples taken at random from production and believed to be representative, E&OE. Page 9 (12) www.ernitec.com...
  • Page 10: Appendix Electronic Board And Terminal Block

    SW Function SW settings HW setting maximum range Not used HW setting 84 m HW setting 105 m Not used HW setting 60 m HW setting 75 m Anti-vandal function Mounting high / low Not used Page 10 (12) www.ernitec.com...
  • Page 11: Appendix Two Way Communication Rs 485

    Please see the PIRIF-485/2 Installation and Setup Manual, for further details. Page 11 (12) www.ernitec.com...
  • Page 12: Appendix Specification

    0.34 mm … 1.5 mm (AWG 28 … 16) Environmental –20°C … +60°C –40°C … +60°C Operating Temperature (–4ºF … +140ºF) (–40ºF … +140ºF) Humidity 95 % RH max. Sealing IP 64 splash proof 22.1 Mechanical Dimensions Page 12 (12) www.ernitec.com...