Installation Manual Ernitec Eagle PIR-100 & 100H Long-Range Curtain Detectors for Perimeter Protection Outdoors Version 2.0 and higher 06/2008 Highlights • Gap-Free Coverage with Creep Zones • 4 Meter (13 Feet) Mounting Height • Advanced Tamper Detection Standard Models • Low Power Consumption – Ideal for Wireless and •...
Output logic and function can be changed using the installation software. During turn-on time the relay output is in alarm state! Cover Switch To detect attempts to open the detector, a switch is fitted for the cover. Its contact opens when the cover is opened. Page 4 (12) www.ernitec.com...
(see Fig. 2 below). Movement within the field of view will reduce the sensitivity of the PIR by increasing the alarm threshold level and may lead to unwanted alarms. Top view Fig. 2 Page 5 (12) www.ernitec.com...
If the Installation software is used for monitored walk tests and the DIP – Switches 1 and 2 are set to software settings (on – on), the threshold level can be kept to its nominal value by changing the configuration of the ATD to „off“ for this test. Page 6 (12) www.ernitec.com...
13 Internal Heater (H version only) A regulated heater connected to the electronic board and powered by the supply voltage of the PIR-100H prevents the optical surfaces from fogging or frosting and maintains the internal temperature at optimal levels. Page 7 (12) www.ernitec.com...
If more than one detector is connected to the same RS 485 communication bus, each detector needs to have a different address (ID). Please see the PIRIF-485/2 Installation and Setup Manual, for further details. 16.2 Pole Mount Hardware ZA P-L1 Pole mounting bracket with two strap bands for poles of 4 – 16 cm diameter Page 8 (12) www.ernitec.com...
• Any liability for direct or indirect damage resulting from the use of the PIR as a detection device is explicitly disclaimed. • The information in this product manual is based on testing of samples taken at random from production and believed to be representative, E&OE. Page 9 (12) www.ernitec.com...
SW Function SW settings HW setting maximum range Not used HW setting 84 m HW setting 105 m Not used HW setting 60 m HW setting 75 m Anti-vandal function Mounting high / low Not used Page 10 (12) www.ernitec.com...