Introduction

Congratulations on your purchase of the Triplett TMP50 Type K/J
Thermometer This meter. This single input contact thermometer offers fast
response and laboratory accuracy and works with K-type or J-type
thermocouples as temperature sensors and offers a 0.1 0C/0.1 0 F resolution.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TMP50 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Triplett TMP50

  • Page 1 TMP50 Type K/J Thermometer Introduction Congratulations on your purchase of the Triplett TMP50 Type K/J Thermometer This meter. This single input contact thermometer offers fast response and laboratory accuracy and works with K-type or J-type thermocouples as temperature sensors and offers a 0.1 0C/0.1 0 F resolution.
  • Page 2 Safety  Do not operate the meter in environments where the following are present: explosive gases (or materials), combustible gases (or materials), steam, or dust.  Please replace the battery immediately when the low battery symbol appears on the LCD. ...
  • Page 3 Display Entering/Exiting Setup Icon Offset Option Icon HOLD Icon APO Status Icon Primary Display: T1 Reading Units Icon Secondary Display – MAX/MIN/AVG/OFFSET MIN/MAX/AVG Icon Time Display 10. Min: Sec or Hour: min Display 11. Thermocouple Type Icon 12. Low Battery Indicator Icon Operation Connecting thermocouples This meter accepts a K/J-type thermocouple with spade lugs (sub-...
  • Page 4 Press the C-F-K button to select the desired temperature unit of measure. A display icon will reflect the selection. Touch the object to be measured with the probe. Read the measured temperature on the display. Note: If the display indicates “OL” the temperature is outside the measurement range.
  • Page 5 Press and hold the SET button for 3 seconds to enter or exit the Setup mode. When the thermometer is in Setup mode, the display shows the SETUP display icon. Set Type J or K thermocouple Press ▲ or ▼to scroll to the “TYPE” setting (shown on the bottom left of the display).
  • Page 6 Place the thermocouple into the known, stable temperature environment (such as an ice bath or dry well calibrator). Allow the reading to stabilize. Use the arrow keys ▲ ▼ to scroll to the “T1” option and then press ENTER. Change the offset temperature reading (upper display) by pressing ▼until the desired temperature is reached.
  • Page 7 Triplett / Jewell Instruments extends the following warranty to the original purchaser of these goods for use. Triplett warrants to the original purchaser for use that the products sold by it will be free from defects in workmanship and material for a period of (1) one year from the date of purchase.