CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES

1. OPERATING PROCEDURES
1 – 1. SERVICE MENU 1
Used to display the model name, the manufacturing No., the
firmware version/checksum, and the usage time.
Model name
MODEL
Serial number
S/N
Main firmware1 version
VER(MAIN1)
Main firmware2 version
VER(MAIN2)
SUB firmware version
VER(SUB)
Firmware1 version of the touch panel
TPC1
*K322B only
Firmware2 version of the touch panel
TPC2
*K322B only
Usage time
USAGE TIME
When the white balance setting is reset
ADJUSTMENT
to the initial value after replacement of
CHECK
the PWB or the panel, "W/B" is
displayed.
1) Press [INPUT/RETURN] and [MENU/ENTER] on right side of
the machine simultaneously (for 5 seconds or longer) or press
MENU and move the cursor to "OTHER" and press [BRIGHT -
()], [BRIGHT + ()], [BRIGHT - ()], [BRIGHT + ()]. After "F"
is displayed on upper left corner of the screen, press [INPUT],
[MENU], [INPUT], and [MENU] or [BRIGHT - ()], [VOL - ()],
[BRIGHT + ()], and [VOL + ()].
SERVICE MENU1 appears.
<MEMO>
*Immediately after turning on the power, "CALCULATING" is
displayed for the checksum for a while, and the result is dipslayed.
*"F" mark is displayed in red when the adjustment lock is set to
other than "Not" and displayed in blue when the OSD display is
set to "Not." For the other cases, it is displayed in green.
(The red color of "F" mark takes priority. )
PN-K321 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4 - 1
1 – 2. SERVICE MENU 2
AGING.
AGING
>Refer to page 4 - 3 "2. AGING".
Used to reset the user adjustment
FACTORY
values, the usage time, and the
RESET
operation logs to the factory setting.
>Refer to page 4 - 3 "3. FACTORY
RESET".
Used to select the destination.
MODEL TYPE
JP: Japanese model
US: North American model
CN: Chinese model
EU: European model / Australia
EUH:Europe model(Not HDMI)
Used to display the hardware
HARDWARE
detection result.
CHECK
Do not change ON/OFF of the
detection.
>Refer to page 4 - 4 "4.
HARDWARE CHECK".
>Refer to page 4 - 13 "7. WHITE
WHITE
BALANCE SETTING PROCEDURES
BALANCE
BY OSD" and page 4-16 " 8. WHITE
SETTING
BALANCE SETTING TOOL
OPERATING PROCEDURE".
Used to update firmware
FIRMWARE
>Refer to page 5-1 "FIRMWARE
UPDATE
UPDATE
PROCEDURE"
The GAMMA is set.
GAMMA
>Refer to page 4 - 18 "9. GAMMA
SETTING
SETTING PROCEDURES WITH THE
OSD" and page 4-20 "10. GAMMA
SETTING TOOL PROCEDURES.
1) With "SERVICE MENU1" displayed, select "SERVICE2" with
[VOL-()] button and press [MENU] button.
2) Select setting item with [VOL+ ()] [VOL- ()] button.
3) Adjust it with the [BRIGHT- ()] [BRIGHT+ ()] button.
When the item with => mark press [ENTER] button and
advances to the next screen.
4) Press [INPUT/RETURN] button to terminate the operation.