Download Print this page

Electrolux EKM 101199 X Instruction Booklet page 11

Hide thumbs Also See for EKM 101199 X:

Advertisement

We recommend to check wether the appliance has
been foreseen for the kind of gas distributed.
The appliance must be connected to the gas piping
in a workmanlike way and in conformity with the
regulations in force which lay down the installation
of a safety valve at the end of the piping.
For butane and propane a pressure reducer
conforming to the standards in force may perform
this task. The seal gaskets must be in accordance
with rules.
The appliance must be connected with the gas
pipeline by means a rubber tube in accordance
with rules.
This tube must be connected directly on the push
on connector and it must be blocked with a band
(see
Fig. 9).
In the last case, check the tube's printed date of
expiry and replace it before this date.
Once the gas appliance has been connected, check
the connection seal by means of soapy water.
Fig. 9
Concerning rubber flexible tubes, we remember
you:
1 - to avoid the tube to be narrowed or crushed
2 - do not submit it to traction or torsion efforts
3 - to avoid contact with sharp edges, etc...
4 - to avoid contact with parts reaching
temperatures over 70°C the ambient
temperature
5 - to ensure that they can be checked for all their
length.
All manuals and user guides at all-guides.com
11
The cookers can be set for supply both on the right
or lefthand side (fig 10). In this case it is sufficient
to reverse the position of the cad nipple reducer.
At the end make sure than there is no leakage of
gas.
Stop
If the connecting tube must be passed behind the
appliance, observe the regulations of the picture
11.
Fig. 11
Fig. 10
Inlet

Advertisement