This phenomenon, besides being very rare, does no harm to the system, but it is necessary to
reset the valve with the following simple procedure:

RESET PROCEDURE

1. Turn the system off.
2. Open the reset valve (lever in horizontal position).
3. Screw the positioner knob clockwise until it can be moved no further.
10 turns at least are necessary.
4. Unscrew the positioner knob up to the original position, until when it is blocked
back.
5. Close the reset valve (lever in vertical position).
6. Restart the system