M.2 pinouts for M.2 2280 and M.2 2242 All company names, brand names, and product names referred to in this manual are registered or unregistered trademarks of their respective holders and are, as such, protected by national and international law. page 6 ADL Embedded Solutions E3800HDC...
Via our website at www.adl-usa.com/support or www.adl-europe.com/support 1.3 Warranty This product is warranted to be free of defects in workmanship and material. ADL Embedded Solutions' sole obligation under this warranty is to provide replacement parts or repair services at no charge, except shipping cost.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. page 8 ADL Embedded Solutions E3800HDC...
BIOS AMI® Aptio V 16V - 36V input voltage range Power Supply Over- and undervoltage protection S-UPS connection Reverse voltage protection not galvanically isolated Format 102 mm x 147 mm page 10 ADL Embedded Solutions E3800HDC...
M.2 cards can be easily inserted: just plug them into the slot and fix it with a fixing screw. Cards of different types have different keyings. Depending on the supported type, one port can receive add-in cards of one ore various types: page 12 ADL Embedded Solutions E3800HDC...
Page 13
G, H, J, K, L Reserved PCIe x4, SATA and SMBus * With its M.2 socket the ADLE3800HDC supports keying B M.2 modules. For optimal driver compatibility we recommend the use of a Microsoft® OTICE Windows® 8 operating system. ADL Embedded Solutions E3800HDC page 13...
USB 2.0 requires twisted and shielded cables to reliably maintain full speed data rates. Restrictions on maximum cable length are also in place for many high speed interfaces and for power supply. Please refer to the respective specifications and use suitable cables at all times. page 14 ADL Embedded Solutions E3800HDC...
"DVI/HDMI/DisplayPort and USB3.0" p. 32 P1005 "SATA Interface" p. 34 P1006 "S-UPS" p. 19 P1100/2/4 "LAN" p. 24 P1101/3 "USB" p. 23 P1105 "DVI / HDMI / VGA" p. 21 P1106 "Mainboard Power Supply" p. 16 ADL Embedded Solutions E3800HDC page 15...
2 (PC_AKTIV) is pulled from 24V to 0V. Description Mating Connector Manufacturer Phoenix P20THR-1787014 DFMC 1,5/ 2-ST-3,5-LR- 1790292 Name Name Description Description PC Start PC_START PC_AKTIV PC Status Power Supply 24V Ground page 16 ADL Embedded Solutions E3800HDC...
FCI 90311-012LF Pinout power connector 2x6: Name Name Description Description power supply 5V power supply 5V power supply 5V ground ground ground ground ground power supply 12V ground power supply 12V power supply 12V ADL Embedded Solutions E3800HDC page 17...
Maximum current is 2 amperes for VCC combined (2A per contact), and also 2 amperes for 12V and 3,3V (2A per contact). Description Mating Connector Manufacturer 98424-G52-08LF 90311-008LF Pinout power connector 2x4: Name Name Description Description battery (Input) BATT_E ground power supply 3,3V 3,3V ground power supply ground power supply ground page 18 ADL Embedded Solutions E3800HDC...
DVI data 1 - TMDSDAT1 DVI data 1 + ground reserved reserved 5 volt supply ground HP_DETECT hot plug detect TMDSDAT0# DVI data 0 - TMDSDAT0 DVI data 0 + ground reserved reserved ground ADL Embedded Solutions E3800HDC page 21...
Page 22
Chapter: Connectors Front Panel Connectors Name Description TMDS CLK DVI clock TMDS CLK# DVI clock C_RED VGA red C_GREEN VGA green C_BLUE VGA blue C_HSYNC VGA horizontal synchronization ground page 22 ADL Embedded Solutions E3800HDC...
In ACPI state S5 via USB connected devices will not be energized. Description Mating Connectors Manufacturer Foxconn UB11121C-8D1-4F (standard connector) Pinout USB2.0 connector for channel X: Name Description 5 volt for USBX USBX# minus channel USBX USBX plus channel USBX ground ADL Embedded Solutions E3800HDC page 23...
LAN channel 0 minus LAN-1 LAN channel 1 plus LAN-2 LAN channel 2 plus LAN-2# LAN channel 2 minus LAN-1# LAN channel 1 minus LAN-3 LAN channel 3 plus LAN-3# LAN channel 3 minus page 24 ADL Embedded Solutions E3800HDC...
1 + DQS1 RESET# Reset ground ground data 10 DQ10 DQ14 data 14 data 11 DQ11 DQ15 data 15 ground ground data 16 DQ16 DQ20 data 20 data 17 DQ17 DQ21 data 21 ADL Embedded Solutions E3800HDC page 25...
Page 26
DQ38 data 38 data 34 DQ34 DQ39 data 39 data 35 DQ35 ground ground DQ44 data 44 data 40 DQ40 DQ45 data 45 data 41 DQ41 ground ground DQS5# data strobe 5 - page 26 ADL Embedded Solutions E3800HDC...
Page 27
58 DQ58 DQ62 data 62 data 59 DQ59 DQ63 data 63 ground ground SPD address 0 EVENT# Event 3.3 volt supply 3.3V SMBus data SPD address 1 SMBus clock termination current termination current ADL Embedded Solutions E3800HDC page 27...
SEL_DVI/DP# DVI-DisplayPort Select DDCK/DPAUX EDID Clock / DP Aux + DDDA/DPAUX# EDID Data / DP Aux - 5V supply ground hot plug detect USBVCC 5V supply for USB USBVCC 5V supply for USB page 32 ADL Embedded Solutions E3800HDC...
Page 33
Super Speed receiver - SSRX Super Speed receiver + USB# USB - USB + SSTX# Super Speed transmitter - SSTX Super Speed transmitter 3.3V 3.3V supply 3.3V 3.3V supply 5V supply 5V supply 5V supply ADL Embedded Solutions E3800HDC page 33...
The required settings are made in the BIOS setup. Description Mating Connector Manufacturer Amphenol SATA-001-22223-CTR (standard connector) Pinout SATA: Name Description ground SATATX SATA transmit + SATATX# SATA transmit - ground SATARX SATA receive - SATARX# SATA receive + ground page 34 ADL Embedded Solutions E3800HDC...
They do not represent the recommended settings or the default settings. Determination of the appropriate settings is dependent upon the particular application scenario in which the board is used. ADL Embedded Solutions E3800HDC page 35...
Options: none BayTrail SoC Options: none Total Memory Options: none System Date Options: The system date can be adjusted here. System Time Options: The system time can be adjusted here. page 36 ADL Embedded Solutions E3800HDC...
Sub menu: see "Network Stack" (page 47) Power Controller Options Sub menu: see "Power Controller Options" (page 48) CSM Configuration Sub menu: see "CSM Configuration" (page 49) NVMe Configuration Sub menu: see "Advanced-Menü-NVMe Configuration" (page 50) ADL Embedded Solutions E3800HDC page 37...
Page 38
Security Configuration Sub menu: see "Security Configuration" (page 53) Intel(R) Gigabit Network Connection Sub menu: see "Intel(R) I210 Gigabit Network Connection" (page 54) Driver Health Sub menu: see "Driver Health" (page 56) page 38 ADL Embedded Solutions E3800HDC...
└─────────────────────────────────────────────────────────────────┴────────────────────────────────┘ Version 2.17.1249. Copyright (C) 2016 American Megatrends, Inc. CPU C state Report Options: Disabled / Enabled Max CPU C-state Options: C7 / C6 / C1 S0ix Options: Disabled / Enabled page 44 ADL Embedded Solutions E3800HDC...
Storage Options: Do not launch / UEFI only / Legacy only Video Options: Do not launch / UEFI only / Legacy only Other PCI devices Options: UEFI only / Legacy only ADL Embedded Solutions E3800HDC page 49...
Options: none Chip Type Options: none PCI Device ID Options: none PCI Address Options: none Link Status Options: none MAC Address Options: none Virtual MAC Address Options: none page 54 ADL Embedded Solutions E3800HDC...
Page 55
Version 2.17.1249. Copyright (C) 2016 American Megatrends, Inc. Link Speed Options: Auto Negotiated / 10Mbps Half / 10Mbps full / 100Mbps Half / 100Mbps Full Wake On LAN Options: Enabled / Disabled ADL Embedded Solutions E3800HDC page 55...
│ │ │ │ │ └─────────────────────────────────────────────────────────────────┴────────────────────────────────┘ Version 2.17.1249. Copyright (C) 2016 American Megatrends, Inc. North Bridge Sub menu: see "North Bridge" (page 59) South Bridge Sub menu: see "South Bridge" (page 63) page 58 ADL Embedded Solutions E3800HDC...
Restore AC Power Loss Options: Power Off / Power On / Last State Onboard Gigabit LAN X Options: Enabled / Disabled M.2-PCIe Configuration Pins Options: none M.2-SATA Configuration Pins Options: none ADL Embedded Solutions E3800HDC page 63...
Page 65
│ └─────────────────────────────────────────────────────────────────┴────────────────────────────────┘ Version 2.17.1249. Copyright (C) 2016 American Megatrends, Inc. USB Mode Options: EHCI / XHCI USB Per Port Control Options: Enabled / Disabled USB Port x Options: Disabled / Enabled ADL Embedded Solutions E3800HDC page 65...
Page 66
│ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ └─────────────────────────────────────────────────────────────────┴────────────────────────────────┘ Version 2.17.1249. Copyright (C) 2016 American Megatrends, Inc. PCIe Port x is assigned to Options: none page 66 ADL Embedded Solutions E3800HDC...
Legacy / UEFI / DUAL Fixed Boot Order Priorities Options: Review or change the sequence of available boot devices Advanced Fixed Boot Order Parameters Sub menu: see "Advanced Fixed Boot Order Parameters" (page 71) page 70 ADL Embedded Solutions E3800HDC...
BIOS file which was issued for the exact board and exact board revision that you wish to update. If you try to update the BIOS using the wrong file the board will not start up again. ADL Embedded Solutions E3800HDC page 73...
PCB: Mounting Holes 6 Mechanical Drawings All dimensions are in mil (1 mil = 0,0254 mm) OTICE 6.1 PCB: Mounting Holes A true dimensioned drawing can be found in the PC/104 specification. 1102 1300 2750 3858 page 74 ADL Embedded Solutions E3800HDC...
The figure below includes all hole spacing for each heat spreader available and can be used to aid in mating the heat spreader to a bulkhead or chassis. Dimensions are in inch (1 in = 2.54cm; 1 mil = 0.0254 mm) page 78 ADL Embedded Solutions E3800HDC...
5 up to 9Hz, 3.5mm amplitude 9 up to 500Hz, 10m/s , for packaged boards Shock and vibration figures pertain to the motherboard alone and do not OTICE include additional components such as heat sinks, memory modules, cables etc. ADL Embedded Solutions E3800HDC page 79...
100°C. Permanent overheating may destroy the board! In case the temperature exceeds 100°C the environmental temperature must be reduced. Under certain circumstances sufficient air circulation must be provided. page 80 ADL Embedded Solutions E3800HDC...
(POST code card). The meaning of these codes is described in the document "Aptio™ 4.x Status Codes" by American Megatrends®, which can be downloaded from their website http://www.ami.com. The following additional OEM POST codes are generated: Description Code BIOS-API started PCA9535 started PWRCTRL-Firmware started page 82 ADL Embedded Solutions E3800HDC...
The exclusivity is not given and not possible on the PCI side. Function Adress IRQ0 Timer IRQ1 PS/2 Keyboard IRQ2 (8) IRQ3 COM2 IRQ4 COM1 IRQ5 IRQ6 IRQ7 IRQ8 IRQ9 IRQ10 IRQ11 IRQ12 IRQ13 IRQ14 ADL Embedded Solutions E3800HDC page 83...
Need help?
Do you have a question about the E3800HDC and is the answer not in the manual?
Questions and answers