INSTALLATION – Configuration – Frequency Control
In order to configure the Solar Relay to use Frequency Control mode follow these
steps.
1)
Set up one of the four system overrides to be Frequency Controlled.
2)
Configure the Frequency Control parameters as described below.
Minimum On Time: Specifies the minimum
time the load must stay on once it has been
turned on.
Above Threshold: The frequency at which the
Solar Relay will turn the load on.
Above Time: The number of minutes the
Above Threshold needs to occur before the
load turns on.
Below Threshold: The frequency at which the
Solar Relay will turn the load off.
Below Time: The number of minutes the
Below Threshold needs to occur before the
load turns off.