Download Print this page
Orbit 27954 Installation Manual & Users Manual

Orbit 27954 Installation Manual & Users Manual

Advertisement

Quick Links

All manuals and user guides at all-guides.com
n
n
Remove batteries when depleted or if product is to
be left unused for a long time. The program will be
retained for up to 30 seconds while the batteries are
replaced.
Installation Manual /
Do not mix old and new batteries. Do not mix alkaline,
standard (carbon - zinc), or rechargeable (nickel
User's Manual
cadmium) batteries.
Weak or missing batteries can cause the time and date
to be erased after a power failure.
Set the Time of Day and Date
If this is the first time the timer has been programmed,
you should press the small recessed button labeled
RESET. Pressing RESET does not affect the factory
installed fail-safe program [See Figure 2].
n
n
MODELS: 27954, 27956, 57114, 57161, 57162,
n
91046, 91054, 94122, 94124, 94126
WT2x version
n
Introduction
n
n
Thank you for selecting an Orbit
sprinkler timer.
®
Orbit
designers have combined the simplicity of
®
mechanical switches with the accuracy of digital elec-
n
tronics to give you a timer that is both easy to program
and extremely versatile. The Orbit
timer provides
®
convenience and flexibility, letting you run a fully auto-
matic, semi-automatic, or a manual watering program
for all your watering needs.
Please read this manual completely before you begin
to program and use the controller. A few of the most
notable design features include:
At-a-Glance Simplicity
By turning the rotary dial to one of nine settings you can
review programming or easily make changes.
Caution: If a watering schedule is not entered into the
Arm Chair Programmable
timer, the factory installed fail-safe program will turn on
By inserting two AA alkaline batteries you can program
each station every day for 10 minutes. To avoid accidental
the timer prior to installing it in its permanent location.
valve activation, either turn the rotary dial to OFF or enter
a watering schedule.
Fuse
The 0.75 amp slow-blow fuse provides circuit
Establish a Watering Schedule
protection. For replacement, use WaterMaster 0.75
amp fuse or equivalent.
To help you visualize how best to program the timer,
it might be helpful to make a watering plan on paper.
Lexan Language Covers
This will help you establish which days and times you
Available in English, French, Spanish, Italian, and
want to water.
German.
1. Digital Display
Programming
A large LCD (Liquid Crystal Display) shows the time of
day and indicates many of the programming settings.
The display is completely interactive with all other
controls.
The timer has two programs you can set up to control
a variety of watering schedules. Depending on your
2. Programming Keys
needs, you can use either or both programs.
The timer has seven push button keys for setup and
program entry. Working in conjunction with the rotary
Enter Watering Schedule in Any Order
selector, the keys are used to set the time of day,
watering time, watering days, start times, and other
You have the option of entering your watering schedule
functions.
in whatever order you like. This feature makes it very
easy to review and change your watering schedule.
3. Selector Dial
Your settings can be changed at any time while you're
This large dial makes it easy to see which function is
setting up the initial schedule or even after years of
currently selected and/or in which mode the timer is
operation.
set to operate.
Start Times for Program A or B
4. Reset Button
The reset button clears the time, date, and user-defined
note: A start time is the time of day that the program
programming, but does not remove the factory installed
begins watering the first station, and all other stations in
fail-safe program. To prevent an accidental reset, the
the program will then follow in sequence. There are not
button is recessed into the panel and must be pressed
separate start times for each station. Start times do not
with a small pointed object such as a pen or pencil tip.
correspond to specific stations, but to programs (A or B).
If you enter more than one start time, all stations in the
specified program will water again (in sequence).
1
n
3
4
2
FIGURE 1: Location of Controls on the Timer
Notable Programming Features
Two Watering Programs—Summary
The timer gives you the option of using one or both of
n
the independent programs. Note that each station can
independently be set to either A or B or both A and B
programs.
Program A
This program lets you schedule selected stations to
water on specific days of the week or to water every 2nd
day. Program A repeats itself continuously in successive
weeks.
Program B
n
Provides two options: One for odd or even day watering
or for intervals ranging from everyday to every 28th
day. This feature is designed to meet the growing needs
and restrictions imposed by local governments and
to conserve water. The timer automatically calculates
odd and even days (by date) for each month and makes
adjustments for leap years to provide true odd and even
watering through the year 2100.
Start-Time Stacking
The timer has the intelligence to "stack" start times
that overlap. If you enter two or more start times that
overlap (in the same or in different programs), the
timer will not activate two stations at the same time.
Instead, the timer activates the first station and then
Water Duration for Program A or B
activates the next station(s) in sequence after the
first station finishes its preset watering duration. The
note: Both programs require watering durations to be
timer will NOT stack to the next calendar , preventing
programmed.
the timer from violating an odd or even day watering
n
schedule.
Manual and Semi-Automatic Modes
The timer gives you a number of manual and semi-
automatic modes for flexibility in watering. You can
override the timer's automatic programming in a
variety of ways.
Getting Started
Programming the timer can be accomplished in just
a few basic steps. Before you begin programming,
it is important to install the batteries (batteries not
included), set the time of day and date, and establish a
watering plan.
Install the Batteries
n
The timer requires two AA batteries to maintain the
time, date, and programs in case of AC power loss. In
a typical installation, fully charged batteries should
provide sufficient power for approximately three years
of operation.
n
Remove the terminal cover.
n
Insert two AA batteries into the battery
n
compartment (batteries not included).
n
Return the terminal cover to its closed position.
Assigning Watering Days for Program A
n
n
FIGURE 2: Programming Keys
n
Turn the rotary dial to the TIME/DATE position
n
[See Figure 3].
n
12:00 AM will appear in the display with three
arrows pointing to the year, month, and day.
note: If you choose to water every 2nd day, you cannot
Use the + and - keys to set the correct time of day.
set specific days of the week for watering
When the correct time of day is reached, press
the ENTER key to lock in the time. To increase or
Assigning Watering Intervals for
decrease more rapidly, hold down either the + or –
Program B
keys until the display goes into rapid advance mode.
A blinking cursor will appear below the arrow for
Program B is used to water at specific intervals
the year, month, and date when programming [See
between days (1 to 28), or on odd or even calender
Figure 3].
dates. The timer has a leap-year compensator and
Use the + and – keys to set the correct year, then
will ensure conformance to the odd and even schedule
press ENTER.
through the year 2100.
Use the + and – keys to set the correct month, then
n
press ENTER.
Use the + and – keys to set the correct date, then
press ENTER.
5 : 00
FIGURE 3: LCD Display with Surrounding Information
n
n
note: If an interval of 3 is entered today, the timer will
water for the first time today, and then again every 3 days.
n
n
Reviewing and Changing your Program
The Orbit timer lets you easily review a complete
watering plan.
For example, to review Program A watering start
times, simply turn the rotary dial to the CyCLE START
TIMES position in Program A and check the times
that have been entered. Using the NExT key, you
can advance through the schedule without fear of
disturbing any programming. If you want to change the
start times, watering days, or interval, simply follow
the directions for that program. After reviewing or
changing a watering schedule, remember to turn the
rotary dial back to AUTO.
Ready for Automatic Operation
After programming is complete, turn the rotary
dial to AUTO [See Figure 8]. The timer is now fully
programmed and ready to use in the automatic
mode. In automatic mode, each program will operate
sequentially, starting with Program A
The way you set the cycle start time is the same for
both programs. Turn the rotary dial to the CyCLE
START TIMES position in the program that you want
to set. The display will show an A or B depending on
which program you have selected. The display will
show —— : ——
and a blinking cursor in CyCLE START 1 location
Semi-Automatic &
[See Figure 4].
Set the time you want to begin watering for start
Manual Operation
time 1 using the + or – keys, then press the
ENTER key. The display will advance to
2. For
stArt
additional start times, simply repeat this procedure
The Orbit timer has the ability to override the
by using the + and – keys to enter the time and
automatic program without disturbing the preset
then press ENTER. Remember, Each start time
program.
will activate all stations that are set to water in the
specified program. There are not separate start times
Using the Semi-Automatic Mode
for each station. Start times do not correspond to
(All stations cycle once both A & B programs)
specific stations.
Up to four start times can be entered per program
n
(A or B).
n
FIGURE 4: LCD Display with Start Time
note: Water durations assigned to station 1 in program
A will water first, then move to station 1 in program B
Turn the rotary dial to STATION DURATION position in
before advancing to the second station and will continue
alternating. Only those stations assigned a watering
either the A or B program. The display will show which
duration will water when using the manual or semi-
program you have selected with an "A" or "B" and the
automatic mode [See Figure 10].
- - cursor blinking at station "1" [See Figure 5].
FIGURE 5: Station Duration for Program A
You can set the watering duration from 1 to 99
(All stations cycle once, A program only)
minutes. Press and hold the + key to advance
the number of minutes, or use the - key to go in
n
reverse, then press ENTER. When the minutes are
set, "A" or "B" will appear over station 1 and the
cursor will advance to station 2 and begin blinking.
Simply repeat these steps to set watering durations
for all zones on this program
To skip a station, press the NExT key.
To erase previously programmed watering
durations, press the CLEAR key.
Turn the rotary dial to DAy OF WEEK in program
A. The display will show an "A" and the cursor will
blink under the days of week Monday, Tuesday,
Wednesday, etc. [See Figure 6].
FIGURE 6: LCD Display with Watering Days
Press ENTER to activate watering on Monday. An
arrow appears under M and the cursor will advance
to Tuesday (T), press ENTER to activate watering
on this day. Repeat these steps for all days of the
week.
To skip a day, press NExT.
To delete a previously entered day, press CLEAR
If you want to water every second day, press the
NExT key to advance the cursor to "2nd", then press
ENTER.
Turn the rotary dial to WATERING INTERvAL. The
cursor will blink to the left of the word INTERvAL
[See Figure 7].
FIGURE 7: LCD Display with Watering Interval
Press and hold the + or - keys to select the number
of days between watering. example: If you want to
water once every 10 days, set the interval at 10.
To activate the watering interval, press ENTER.
To select odd or even day watering, press NExT.
The cursor will move to either the odd or even
setting, then press ENTER.
To erase a schedule, press CLEAR. To enter a new
schedule, press NExT.
FIGURE 8: Ready for Automatic Operation
Turn the rotary dial to AUTO, then press the
MANUAL key. The display will show AB, MANUAL,
and ALL will be blinking [See Figure 9]. This
indicates all stations will semi-automatically water
for their assigned durations in sequence.
To activate the assigned water durations in the A and
B programs for each station, press ENTER.
FIGURE 9: Semi-Automatic Watering for Stations
Assigned to A and B Programs
FIGURE 10: Semi-Automatic Watering Entered for A
and B Programs, All Stations
To activate stations assigned watering duration
for the A program only, press the MANUAL key,
followed by the NExT key. This will activate stations
with assigned watering durations in the A program
only. To initiate this semi-automatic watering, press
ENTER [See Figure 11].

Advertisement

loading

Summary of Contents for Orbit 27954

  • Page 1 Reviewing and Changing your Program Programming A large LCD (Liquid Crystal Display) shows the time of day and indicates many of the programming settings. The Orbit timer lets you easily review a complete The display is completely interactive with all other watering plan. controls.
  • Page 2 • Young children should be supervised to ensure they do Help not play with the controller. FIGURE 12: LCD Display with Manual Operation Before returning this timer to the store, contact Orbit ® Installing Valves, Pump Technical Service at: 1-800-488-6156.

This manual is also suitable for:

279565711457161571629104691054 ... Show all