◢MR6100 Serial UHF reader user manual(Ver 1.0)◣
4. RS485:Reader provide RS485 communication interface(10、11 pin) ,
work as data main output mode,also can connect with PC via serial port,
use RS232-RS485 converter,in this way,RS485 interface support RS232
all supported functions;
5. Programmable
programmable output interface(1、2 pin) ,works as Wiegand output
interface,default is high level(5V) ;one set relay interface(13、14、15
pin) ,relay default status is OFF and COM short circuit
6. Input check port: 2 team input check port (7、 8 pin) , can configure as trigger
read mode,default as Dangling status is high level(5V) ;
7. Power supply port:DC+9V~+15V==4A power port;
8. Antenna port:4 sets TNC antenna port;
9. Indicator light:6 indicator light,including COM port indicator light、power
indicator light and 4 sets antenna indicator light;