Flepcher FLP-MA120U Operation Manual

Flepcher FLP-MA120U Operation Manual

5 zone mixer amplifier

Advertisement

Quick Links

FLP-MA-120U / MA-240U
5 Zone Mixer Amplifier
The FLP-MA120U and MA240U are the latest addition to the MA Series that are versatile and suitable to be deployed in
various PA system. It comes with 5 zones speaker terminals which can be selected individually. The series comes with three
balance microphone inputs, two aux inputs and one EMC input providing more functionality to the PA system. The EMC
input is capable in overriding BGM and able to mute various channels except Mic 1 when it comes to emergency and crucial
situations. With noticeable function buttons and fluorescent screens, users are able to control and navigate the PA system
much more efficiently and effectively.
Product Features
• With USB port and fluorescent screen to display the sound number
• Remote control over USB for EQ, volume up, volume down & mute
• 5 zone and all zone speaker terminals
• Mic 1 with VOX priority and VOX level on rear panel
• Mic 2-3 by phone jack rear on rear panel
Specifications
Rated Power Output
Speaker Outputs
Output Sensitivity & Impedance
Tone
Frequency Response
S/N Ratio
THD
Muting Function
Gain Control
Crosstalk
MP3 Support Format
Maximum Support Capacity
Phantom Power
Cooling
Protection
Power Supply
Power Consumption
Weight
Dimensions (W x D x H)
Finish
DC 24V input
8
FLP-MA120U
120W
MIX OUT: 1000mV/470Ω , Unbalanced RCA output
Bass: ±10dB at 100Hz, Treble: ±10dB at 10KHz
MIC 1, 2, 3: 66dB, AUX 1, 2: 80dB
Less than 0.1% at 1KHz, 1/3 rated power
MIC 1 overrides other input signals with 0-30dB attenuation
MIC2, 3 XLR, ±2.5mV~±75mV at 30dB
Fan automatically start up when temp reaches 55 ºC
High temp, overload & short-circuit
200W
10 kg
484mm x 300mm x 88mm
Zone 1 to 5 speaker
output terminal
Speaker output
Emergency
terminal
input
• Two Aux Inputs and 2 line inputs for spare use
• One EMC priority input
• EMC has priority over all inputs except MIC1
• Support DC 24V power supply
FLP-MA240U
70V, 100V & 4~16Ω
50Hz~16KHz( +1dB, -3dB)
≤50dB
MP3
8GB USB drive
+48V, with LED indicator
~240V/50Hz & 24V DC
484mm x 300mm x 88mm
Panel: aluminium plate, black
Case: steel plate, black
Mic 2 & 3
input
to next amplifier
Mic 2 & 3
AUX 1 & 2
line input
input
240W
400W
17.5 kg
Line output, or

Advertisement

Table of Contents
loading

Summary of Contents for Flepcher FLP-MA120U

  • Page 1 5 Zone Mixer Amplifier The FLP-MA120U and MA240U are the latest addition to the MA Series that are versatile and suitable to be deployed in various PA system. It comes with 5 zones speaker terminals which can be selected individually. The series comes with three balance microphone inputs, two aux inputs and one EMC input providing more functionality to the PA system.
  • Page 2 MIC 3 AUX 1 AUX 2 BASS TREBLE MIC 1 FLP-MA120U FLP-MA240U OPERATION MANUAL Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS 1. SAFETY PRECAUTIONS ..................3 2. GENERAL DESCRIPTION ................... 5 3. FEATURES ........................5 4. NOMENCLATURE AND FUNCTIONS 4.1 Front Panel(2U) .......................6 4.2 Rear Panel(2U)....................... 7 ................7 4.3 REMOTE CONTROL INSTRUCTIONS 5. CONNECTIONS 5.1. Speaker Connections .....................8 5.2....................8 XLR CONNECTIONS MACHINE OPERATION ..................9...
  • Page 4: Safety Precautions

    AC outlet and as doing so may result in fire or electric shock. contact your nearest FLEPCHER dealer. Make no further attempt to operate the unit in this condition Use the unit only with the voltage specified on the as this may cause fire or electric shock.
  • Page 5 When removing the power cord, be sure to hold its plug to pull. Contact your FLEPCHER dealer as to the cleaning. If dust is allowed to accumulate in the unit over Do not block the ventilation slots in the unit's cover.
  • Page 6: General Description

    2. GENERAL DESCRIPTION The USB mixer amplifiers have power ratings from 120W to 240W. They are featured of 3 balanced microphone inputs, 2 AUX inputs and 2 EMC inputs. Priority muting is achieved via EMC1-2 for overriding other inputs except Mic1 on front panel. Individual gain controls are provided for Mic 1-3 and Aux1-2,bass and treble controls and master volume control are provided for overall tone control.70V,100V,and low impedance 4-16ohms speaker outputs are provided.
  • Page 7: Nomenclature And Functions

    4. NOMENCLATURE AND FUNCTIONS 4.1 FRONT PANEL(2U) MP3 PLAYER TEMP PROT OUTPUT LEVEL FLP -MA120U POWER MIXER AMPLIFIER PREV PLAY NEXT MP3 VOL SPEAKER ZONES MASTER MIC 1 MIC 2 MIC 3 AUX 1 AUX 2 BASS TREBLE MIC 1 1.
  • Page 8: Rear Panel(2U)

    NOMENCLATURE AND FUCTIONS NOMENCLATURE AND FUCTIONS 4.2 REAR PANEL(2U) MIC 2 MIC 2 MIC 3 MIC 3 +48V +48V PHANTOM GAIN GAIN PHANTOM COM 100V COM 100V COM 100V COM 100V COM 100V ~240V 50Hz 200W T3.15AL 250V MIC2 MIC3 OUTPUT BATT SUPPLY COM 4-16...
  • Page 9: Connections

    4. Light to take light put the remote control, take precautions against falling. 5. CONNECTIONS 5.1 SPEAKER CONNECTIONS COM 4-16 70V 100V COM 4-16 70V 100V COM 4-16 70V 100V (FLP-MA120U) (FLP-MA120U) (FLP-MA240U) (FLP-MA240U) 100V LINE 4-16 70V LINE 70V/ 5.2 XLR CONNECTIONS...
  • Page 10: Machine Operation

    6. MACHINE OPERATION OPERATION ATTENTION MUTE FUNCTION The four output connectors only can choose two 1 with the first priority over other inputs, connectors work together. If voltage is 70V/100V, the adjustment should be kept within 0-30db the speakers must be with transformer and make with the mute connector, 30db is the original sure the total power wattage of speaker is 15% setting.
  • Page 11: Applications

    7. APPLICATIONS REAR PANEL CONNECTIONS...
  • Page 12: Block Diagram

    8. BLOCK DIAGRAM...
  • Page 13: Specifications

    9. SPECIFICATIONS MIXER AMPLIFIER(2U) MIXER AMPLIFIER(2U) MODEL FLP-MA120U FLP-MA240U RATED POWER OUTPUT 120W 240W SPEAKER OUTPUTS 4~16 ,70V/100V MIC 1:5mV/600 Ohms Unbalanced TRS input INPUT MIC 2.3:5mV/600 Ohms Unbalanced TRS/XLR input MIC2.3:LINE:775mV/10KOhms,Unbalanced RCA input AUX 1. 2:350mV/10KOhms, Unbalanced RCA input...
  • Page 14: Dimensional Diagram

    10. DIMENSIONAL DIAGRAM UNIT:mm MP3 PLAYER TEMP PROT OUTPUT LEVEL FLP -MA120U POWER MIXER AMPLIFIER PREV PLAY NEXT MP3 VOL SPEAKER ZONES MASTER MIC 1 MIC 2 MIC 3 AUX 1 AUX 2 BASS TREBLE MIC 1 MIC 2 MIC 2 MIC 3 MIC 3 +48V...
  • Page 15 Version0.1...

This manual is also suitable for:

Flp-ma240u

Table of Contents