GTE Adicos HTL-2 Operating Manual

GTE Adicos HTL-2 Operating Manual

Hotspot test device

Advertisement

Quick Links

HTL-2
EN
Operating Manual
HOTSPOT Test Device
GTE Industrieelektronik GmbH | Helmholtzstr. 21, 38 – 40 41747 Viersen | Germany | +49 2162 3703-0 | info@gte.de

Advertisement

Table of Contents
loading

Summary of Contents for GTE Adicos HTL-2

  • Page 1 HTL-2 Operating Manual HOTSPOT Test Device GTE Industrieelektronik GmbH | Helmholtzstr. 21, 38 – 40 41747 Viersen | Germany | +49 2162 3703-0 | info@gte.de...
  • Page 2 41747 Viersen GERMANY Support hotline: +49 2162 3703-0 E-Mail: support.adicos@gte.de © 2020 GTE Industrieelektronik GmbH – This document and all figures contained may not be copied, changed, or distributed without explicit approval by the manufacturer! Subject to technical changes! ADICOS and GSME are registered trademarks of GTE Industrieelektronik GmbH.
  • Page 3 In combination with the SOLO 760 battery baton from the company No Climb Products Ltd. (detectortesters.com), the ADICOS HTL-2 serves as a test device for all ADICOS detectors of the type HOTSPOT. ADICOS HTL-2...
  • Page 4: Table Of Contents

    11 Technical information ........15 410-2410-008 EN20 ADICOS HTL-2...
  • Page 5: About This Manual

    (e.g. displays, internal function steps, etc.), they are presented as follows. Intermediate state Warnings signs This manual uses the following information types. DANGER! This type of warning indicates a danger that directly causes death or serious injury. ADICOS HTL-2 410-2410-008 EN20...
  • Page 6: Abbreviations

    Testing system of the company No Climb Products Ltd. for fire detectors HOTSPOT test device 1.4 Storing the instruction manual Store this document close at hand in the carrying case of the test device so you can look up information as needed. 410-2410-008 EN20 ADICOS HTL-2...
  • Page 7: Safety Instructions

    WARNING! Fire and explosion hazard due to hot plate The ADICOS HTL-2 uses a hotplate that can cause fires on contact with foreign bodies or explosions in ex-zones. You must read and comply with this instruction manual in −...
  • Page 8: Qualification Of Staff

    2.4 Modification NOTICE Property damage due to unauthorized change Any form of arbitrary change can cause property damage. A modification of the ADICOS HTL-2 is expressly prohibited! − 2.5 Accessories and replacement parts NOTICE! Property damage through the use of incorrect components The use of parts other than the original spare parts and the original accessories of the manufacturer may result in short-circuit damage.
  • Page 9: Scope Of Delivery

    STRUCTURE Structure Number Description Carrying case HTL-2 test device ADICOS HTL-2 410-2410-008 EN20...
  • Page 10: Construction And Function

    HTL holder  HTL connection element for SOLO 760   Swivel joint HTL control panel  Operating LED (green)  Heating LED (red)  ON/OFF switch  Stop hole for SOLO 760 battery baton  410-2410-008 EN20 ADICOS HTL-2...
  • Page 11: Function

    Heating LED The heating LED is located to the right above the operating switch in the control panel. It shines red when the heating function of the HTL-2 is active. ADICOS HTL-2 410-2410-008 EN20...
  • Page 12: Preparation For Operation

    Preparation for operation 5.1 Removing dirt DANGER! Fire hazard due to deposits Deposits in the test tube of the ADICOS HTL-2 (e.g. carbon dust) can ignite during operation. Clean the device before each use! − 5.2 Charging the battery baton...
  • Page 13: Putting Into Operation

    Do not leave an activated device unsupervised! − DANGER! Burns due to active hot plate The ADICOS HTL-2 uses an active hot plate that can cause severe burns if it comes into contact with the skin. Do not touch the hot plate! −...
  • Page 14: Detector Test

    Use the ADICOS software to call up the detector to be tested Call up the thermal image of the detector Select the tab “Max.-Werte T” In “Zusatz-F .” in the lower-left section, select “Max T” in the window Configure an appropriate color spread 410-2410-008 EN20 ADICOS HTL-2...
  • Page 15: Maintenance

    If it becomes difficult to rotate the HTL-2 swivel joints, blow them out with compressed air Grease the swivel joints with penetrating oil (e.g. WD-40) 9.2 Storage Store the device in its carrying case when it is not in use. ADICOS HTL-2 410-2410-008 EN20...
  • Page 16: Technical Information

    DISPOSAL WARNING Risk of injury from swirling particles When cleaning the ADICOS HTL-2 with compressed air, dirt particles can be whirled up and cause injuries to the eyes and respiratory tract. Wear appropriate protective clothing − 10 Disposal After the end of its utilization time, return the device to the manufacturer, who guarantees environmentally friendly dis- posal of all components.
  • Page 17: Disposal

    DISPOSAL ADICOS HTL-2 410-2410-008 EN20...

Table of Contents