CompuSTAR Firstech CM800-S Installation Manual page 16

Starter only control module
Table of Contents

Advertisement

2-05
Minimum Crank Time - This feature applies to feature 2-02. It will add or remove crank time to
the default setting of the afore mentioned option.
Diesel Timer – Use this option if you can't find the glow plug wire. You can use setting 2 for a
2-06
default wait-to-crank; otherwise, you can adjust the time with your OP-500 Programmer.
Rearm Output – This option changes the events when the orange rearm output will pulse from
2-07
the control module. In the default mode the wire will pulse every time you lock, after remote start
confirmation, and remote start shutdown. Setting 2 only pulses the wire upon lock and remote
start shutdown. Setting 3 pulses the wire upon after remote start only. Setting 4 pulses the wire
upon remote start shutdown only. Optional event to prevent factory alarm from triggering.
Horn Output – This feature changes when the white wire on CN2 will send a pulses.
2-08
2-09
Horn Honk - This feature will change the behavior of horn output (white wire CN2).
2-10
Advanced Tachless - This feature will provide an enhanced Tachless engine sensing mode.
3-01
Secure Auxiliary Output - This feature, in the default option should help prevent accidental
activation of the AUX outputs. 1 Way remotes require the user to hold trunk+start buttons for 2.5
seconds before activating AUX outputs Option setting II turns this feature off.)
3-02
Aux 1 Output - This option determines the duration of the Aux 1 output. Setting 4 allows the
output duration to be set for a specific length of time.
3-03
Aux 2 Output - This option determines the duration of the Aux 2 output. Setting 4 allows the
output duration to be set for a specific length of time.
Aux 1 Output Control – This option sets the condition which controls Auxiliary 1 and how it is
3-04
triggered. Please see the option table 3 for details.
3-05
Aux 2 Output Control - This option sets the condition which controls Auxiliary 2 and how it is
triggered. Please see the option table 3 for details.
Horn Mute Control On Remote – Enabling this option will allow the user to change the horn
3-06
mute on or off using their remote.
Sliding Door (Aux 1, Aux 2) Control for iDatalink Modules – This option changes the activity
3-07
of auxiliary 1 and 2 through iDatalink bypass modules only.
3-08
Connector 2, Pin 4 - This option will change the behavior of the black wire on Connector 2
(CN2). At default the wire will act as a status output but can be changed to (-) ignition, auxiliary 1
or auxiliary 2.
3-09
Connector 2, Pin 5 - This option will change the behavior of the orange wire on Connector 2
(CN2). At default the wire will act as a rearm output but can be changed to (-) ignition, auxiliary 1
or auxiliary 2.
3-10
Connector 2, Pin 6 - This option will change the behavior of the orange/white wire on Connector
2 (CN2). At default the wire will act as a disarm output but can be changed to (-) ignition, auxiliary
1 or auxiliary 2.
3-11
Connector 2, Pin 7 - This option will change the behavior of the white wire on Connector 2
(CN2). At default the wire will act as a horn output but can be changed to (-) ignition, auxiliary 1 or
auxiliary 2.
16

Advertisement

Table of Contents
loading

Table of Contents