Sharp LC-70LE632U Service Manual page 21

Hide thumbs Also See for LC-70LE632U:
Table of Contents

Advertisement

Adjustment
Adjustment conditions
point
10. Key writing
10.1. EDID writing (Main PWB: QPWBXF733WJN2)
Adjustment point
1
HDMI EDID writing
Analog RGB EDID writing
(Main PWB)
10.2. MAC key writing (MAIN PWB: QPWBXF733WJN2)
1. Write the MAC key data on IC8455 mounted on the main PWB.
2. Carry out thorough data management to avoid redundant writing of data.
If the IC where data is written is damaged, replace the PWB since only the IC cannot be changed.
10.3. NETFLIX/WMDRM key writing (MAIN PWB: QPWBXF733WJN2)
1. Write the NETFLIX/WMDRM key data on IC8401 mounted on the main PWB.
2. Carry out thorough data management to avoid redundant writing of data.
If the IC where data is written is damaged, replace the PWB since only the IC cannot be changed.
[Adjustment standard value]
Measuring instrument: [Minolta CA-210] Technical measuring instrument
Point 6
Point 5
Point 4
Point 3
Point 2
Point 1
Remarks
Adjustment conditions
Process mode
Model discrimination check
Adjustment procedure
Level
Reference value
X=0.272
928
y=0.277
X=0.272
776
y=0.277
X=0.272
604
y=0.277
X=0.272
428
y=0.277
X=0.272
288
y=0.277
X=0.272
180
y=0.277
Setting conditions for inspection
AV MODE: [DYNAMIC] (Reset)
Monochro: ON
Active Backlight: OFF
Aging Time: Min. 60 minutes
1) Enter the process mode.
2) Point the cursor to [HDMI EDID WRITE] and press the [ENT]
key.
The writing is complete when [OK] is displayed.
(If not written, HDMI and Analog RGB does not function.)
CAUTION: Perform the data writing after setting the model discrimi-
nation. The data based on the model discrimination
information is recorded in EEPROM.
3 – 14
LC-70LE632U/633U
Adjustment spec
Inspection spec
±0.0010
±0.0020
±0.0010
±0.0020
±0.0015
±0.0030
±0.0020
±0.0040
±0.0030
±0.0060
±0.004
±0.0080
Adjustment procedure

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lc-70le633u